Reference Guide

Recommended
Response
Action
Monitor the disk for other messages or indications of poor health.
Category Storage
SubCategory PDR = Physical Disk
Severity Severity 3 (Informational)
LCD Message No LCD message display defined.
Server
Administrator
Event ID
2331
Server
Administrator
Trap ID
90100
PDR60
Message Error occurred onarg1:arg2.
Arguments
arg1 = physical disk
arg2 = error code
Detailed
Description
The reason for the error can vary depending on the situation. The firmware error
code is indicated in the message.
Recommended
Response
Action
Verify the health of attached devices. Review the Lifecycle log for significant
events. Replace faulty hardware, if required. Make sure the cables are attached
securely. Refer to the storage hardware documentation for more information on
checking the cable connections.
Category Storage
SubCategory PDR = Physical Disk
Severity Severity 2 (Warning)
LCD Message No LCD message display defined.
Server
Administrator
Event ID
2346
Server
Administrator
Trap ID
90300
PDR61
Message The rebuild ofarg1failed due to errors on the source physical disk.
208