Reference Guide
Detailed
Description
The controller has two connectors that are connected to the same enclosure. The
communication path on one connector has lost connection with the enclosure.
The communication path on the other connector is reporting this loss.
Recommended
Response
Action
Make sure the cables are attached securely. See the Cables Attached Correctly
section for more information on checking the cables. Make sure both Enclosure
Management Modules (EMMs) are healthy.
Category Storage
SubCategory PDR = Physical Disk
Severity Severity 2 (Warning)
LCD Message No LCD message display defined.
Server
Administrator
Event ID
2283
Server
Administrator
Trap ID
90300
PDR53
Message A redundant path has been restored forarg1.
Arguments
• arg1 = PD Name
Detailed
Description
This alert is provided for informational purposes.
Recommended
Response
Action
No response action is required.
Category Storage
SubCategory PDR = Physical Disk
Severity Severity 3 (Informational)
LCD Message No LCD message display defined.
Server
Administrator
Event ID
2284
Server
Administrator
Trap ID
90100
204