Reference Guide
Recommended
Response
Action
Assign a larger disk as the global hot spare.
Category Storage
SubCategory PDR = Physical Disk
Severity Severity 2 (Warning)
LCD Message No LCD message display defined.
Server
Administrator
Event ID
2277
Server
Administrator
Trap ID
90300
PDR51
Message Hot sparearg1SMART polling has failed.arg2
Arguments
• arg1 = physical disk
• arg2 = args
Detailed
Description
The controller firmware attempted to do SMART polling on the hot spare but could
not complete the SMART polling. The controller may have lost communication
with the hot spare.
Recommended
Response
Action
Verify the health of the disk assigned as a hot spare. Replace the disk and reassign
the hot spare. Make sure the cables are attached securely. See the storage
hardware documentation for more information on checking the cables.
Category Storage
SubCategory PDR = Physical Disk
Severity Severity 1 (Critical)
LCD Message No LCD message display defined.
Server
Administrator
Event ID
2282
Server
Administrator
Trap ID
90400
PDR52
Message A redundant path is broken.