Reference Guide

Recommended
Response
Action
Add a SATA disk that is large enough to be used as the hot spare and assign the
new disk as a hot spare.
Category Storage
SubCategory PDR = Physical Disk
Severity Severity 2 (Warning)
LCD Message No LCD message display defined.
Server
Administrator
Event ID
2207
Server
Administrator
Trap ID
90300
PDR37
Message Thearg1is not supported.
Arguments
arg1 = physical device
Detailed
Description
The physical device may not have a supported version of the firmware or the
physical device may not be supported.
Recommended
Response
Action
If the physical device is supported, then update the firmware to a supported
version. If the physical device is not supported, then replace the physical device
with one that is supported.
Category Storage
SubCategory PDR = Physical Disk
Severity Severity 2 (Warning)
LCD Message No LCD message display defined.
Server
Administrator
Event ID
2211
Server
Administrator
Trap ID
90300
PDR38
Message A clear operation started onarg1.
Arguments
arg1 = physical disk
196