Reference Guide
LCD Message No LCD message display defined.
Server
Administrator
Event ID
2205
Server
Administrator
Trap ID
90100
PDR35
Message The only hot spare available is a SATA diskarg1.
Arguments
• arg1 = PD Name
Detailed
Description
The only physical disk available to be assigned as a hot spare is using SATA
technology. The physical disks in the virtual disk are using SAS technology. Because
of this difference in technology, the hot spare cannot rebuild data if one of the
physical disks in the virtual disk fails.
Recommended
Response
Action
Add a SAS disk that is large enough to be used as the hot spare and assign the new
disk as a hot spare.
Category Storage
SubCategory PDR = Physical Disk
Severity Severity 2 (Warning)
LCD Message No LCD message display defined.
Server
Administrator
Event ID
2206
Server
Administrator
Trap ID
90300
PDR36
Message The only hot spare available is a SAS diskarg1.
Arguments
• arg1 = PD Name
Detailed
Description
The only physical disk available to be assigned as a hot spare is using SAS
technology. The physical disks in the virtual disk are using SATA technology.
Because of this difference in technology, the hot spare cannot rebuild data if one
of the physical disks in the virtual disk fails.
195