Reference Guide
Recommended
Response
Action
See A Rebuild Completes with Errors for more information.
Category Storage
SubCategory PDR = Physical Disk
Severity Severity 1 (Critical)
LCD Message No LCD message display defined.
Server
Administrator
Event ID
2163
Server
Administrator
Trap ID
90400
PDR30
Message A global hot spare failed.arg1
Arguments
• arg1 = PD Name
Detailed
Description
The controller cannot to communicate with a disk that is assigned as a global hot
spare. The disk either failed or was removed. There may also be a bad or loose
cable.
Recommended
Response
Action
Verify that the disk is healthy and installed. Check the cables. Refer to the product
documentation and see the Cables Attached Correctly section for more
information on checking the cables. If necessary, replace the disk and reassign the
global hot spare.
Category Storage
SubCategory PDR = Physical Disk
Severity Severity 2 (Warning)
LCD Message No LCD message display defined.
Server
Administrator
Event ID
2201
Server
Administrator
Trap ID
90300
PDR31
Message A global hot spare has been removed.arg1
192