Reference Guide
Server
Administrator
Event ID
2160
Server
Administrator
Trap ID
90100
PDR28
Message Dedicated hot spare unassigned fromarg1.
Arguments
• arg1 = PD Name
Detailed
Description
A physical disk that was assigned as a hot spare has been unassigned and is no
longer functioning as a hot spare. The physical disk was unassigned by a user or
automatically unassigned by Storage Management. Storage Management unassigns
hot spares that have been used to rebuild data. Once data is rebuilt onto the hot
spare, the hot spare becomes a member of the virtual disk and is no longer
assigned as a hot spare. Assign a new hot spare to maintain data protection in this
situation.
Recommended
Response
Action
Although this alert is provided for informational purposes, you may need to assign
a new hot spare to the virtual disk. Refer to product documentation and see the
section Protecting Your Virtual Disk with a Hot Spare for more information.
Category Storage
SubCategory PDR = Physical Disk
Severity Severity 3 (Informational)
LCD Message No LCD message display defined.
Server
Administrator
Event ID
2161
Server
Administrator
Trap ID
90100
PDR29
Message Rebuild onarg1completed with error(s).
Arguments
• arg1 = PD Name
Detailed
Description
See A Rebuild Completes with Errors for more information.
191