Reference Guide
is not too hot. Refer to the enclosure documentation for more diagnostic
information. 4) If you cannot identify why the disk has reached an unacceptable
temperature, then replace the disk. If the physical disk is a member of a non-
redundant virtual disk, then back up the data before replacing the disk. Removing a
physical disk that is included in a non-redundant virtual disk causes the virtual disk
to fail and may cause data loss.
Category Storage
SubCategory PDR = Physical Disk
Severity Severity 2 (Warning)
LCD Message No LCD message display defined.
Server
Administrator
Event ID
2109
Server
Administrator
Trap ID
90300
PDR23
Message SMART warning degraded forarg1
Arguments
• arg1 = PD Name
Detailed
Description
A disk is degraded and has received a SMART alert (predictive failure). The disk is
likely to fail in the near future.
Recommended
Response
Action
Replace the disk that has received the SMART alert. If the physical disk is a member
of a non-redundant virtual disk, then back up the data before replacing the disk.
Removing a physical disk that is included in a non-redundant virtual disk will cause
the virtual disk to fail and may cause data loss.
Category Storage
SubCategory PDR = Physical Disk
Severity Severity 2 (Warning)
LCD Message No LCD message display defined.
Server
Administrator
Event ID
2110
Server
Administrator
Trap ID
90300
188