Reference Guide
Server
Administrator
Event ID
2107
Server
Administrator
Trap ID
90400
PDR21
Message SMART warning forarg1
Arguments
• arg1 = PD Name
Detailed
Description
A disk has received a SMART alert (predictive failure). The disk is likely to fail in the
near future.
Recommended
Response
Action
Replace the disk that has received the SMART alert. If the physical disk is a member
of a non-redundant virtual disk, then back up the data before replacing the disk.
Removing a physical disk that is included in a non-redundant virtual disk will cause
the virtual disk to fail and may cause data loss.
Category Storage
SubCategory PDR = Physical Disk
Severity Severity 2 (Warning)
LCD Message No LCD message display defined.
Server
Administrator
Event ID
2108
Server
Administrator
Trap ID
90300
PDR22
Message SMART warning temperature forarg1
Arguments
• arg1 = PD Name
Detailed
Description
A disk has reached an unacceptable temperature and received a SMART alert
(predictive failure). The disk is likely to fail in the near future.
Recommended
Response
Action
Do the following: 1) Determine why the physical disk reached an unacceptable
temperature. For example, a fan failure, incorrect thermostat settings, or the room
temperature may be too hot or cold. 2) Verify that the fans in the server or
enclosure are working. 3) If the physical disk is in an enclosure, check the
thermostat settings and examine whether the enclosure is located near a heat
source. Verify the enclosure has enough ventilation and that the room temperature
187