Reference Guide

Server
Administrator
Event ID
2074
Server
Administrator
Trap ID
90100
PDR12
Message arg1initialization has failed.
Arguments
arg1 = PD Name
Detailed
Description
The physical disk has failed or is corrupt.
Recommended
Response
Action
Replace the failed or corrupt disk. Identify a disk that has failed by locating the disk
that has a red "X" for its status. Restart the initialization.
Category Storage
SubCategory PDR = Physical Disk
Severity Severity 1 (Critical)
LCD Message No LCD message display defined.
Server
Administrator
Event ID
2080
Server
Administrator
Trap ID
90400
PDR13
Message arg1rebuild has failed.
Arguments
arg1 = physical disk
Detailed
Description
A physical disk included in the virtual disk has failed or is corrupted. In addition, you
may have cancelled the rebuild.
Recommended
Response
Action
Replace the failed or corrupt disk, and then start the rebuild operation.
Category Storage
SubCategory PDR = Physical Disk
182