Reference Guide
Arguments
• arg1 = location
• arg2 = type
• arg3 = state
Detailed
Description
An SD card device sensor has detected an irrecoverable error in the SD card.
Recommended
Response
Action
Replace the old SD card with a new SD card.
Category System Health
SubCategory HWC = Hardware Config
Severity Severity 1 (Critical)
LCD Message No LCD message display defined.
Server
Administrator
Event ID
5755
Server
Administrator
Trap ID
HWC8009
Message SD card device sensor value unknown. SD card location:arg1, SD card device
type:arg2, SD card state:arg3.
Arguments
• arg1 = location
• arg2 = type
• arg3 = state
Detailed
Description
An SD card device sensor in the identified system could not obtain a reading.
Recommended
Response
Action
Remove and reinsert the identified SD card.
Category System Health
SubCategory HWC = Hardware Config
Severity Severity 3 (Informational)
LCD Message No LCD message display defined.
Server
Administrator
Event ID
5751
164