Reference Guide

arg2 = details
Detailed
Description
A configuration error was detected for a pluggable device installed at the location
identified in the message. The device may not be installed correctly.
Recommended
Response
Action
Reinsert the device or try inserting a different device of the same type and retry the
operation. If the issue persists, check the system documentation to make sure the
device is supported or contact your service provider.
Category Audit
SubCategory HWC = Hardware Config
Severity Severity 1 (Critical)
LCD Message No LCD message display defined.
Server
Administrator
Event ID
5653
Server
Administrator
Trap ID
5653
HWC8004
Message The SD card device sensor has failed. SD card location:arg1, SD card device
type:arg2, SD card state:arg3.
Arguments
arg1 = location
arg2 = type
arg3 = state
Detailed
Description
The SD card device sensor of the type identified in the messaage has failed. The
current status of the SD card is also displayed.
Recommended
Response
Action
Reinsert the SD card or try a different SD card and retry the operation. If the issue
persists, do one of the following to resolve the error: 1) If the SD card sensor is
installed on the internal SD module, replace the module. 2) If the SD card sensor is
embedded on the system board, replace the system board. . For more information,
contact your service provider.
Category System Health
SubCategory HWC = Hardware Config
Severity Severity 1 (Critical)
LCD Message No LCD message display defined.
Server
Administrator
Event ID
5750
161