Reference Guide
FLDC1032
Message The cache device with WWN =arg1and path =arg2is no longer functional.
Arguments
• arg1 = wwn name
• arg2 = path name
Detailed
Description
The PCIeSSD cache device identified in the message is no longer functional.
Recommended
Response
Action
Replace the non-functional PCIe SSD.
Category Storage
SubCategory FLDC = Unknown
Severity Severity 1 (Critical)
LCD Message No LCD message display defined.
Server
Administrator
Event ID
2900
Server
Administrator
Trap ID
90400
FLDC1033
Message The storage device WWN =arg1and path =arg2is either inaccessible or no longer
functional.
Arguments
• arg1 = wwn name
• arg2 = path name
Detailed
Description
The message indicates that the storage device is either inaccessible or is no longer
functional.
Recommended
Response
Action
If the virtual disk is inaccessible, restore accessibility by bringing the virtual disk
back online. After the virtual disk is accessible, run the following command to
reactivate disk, "omconfig storage vdisk action=reactivate controller=id vdisk=id
devicename=<string>". If the device is no longer functional, replace it.
Category Storage
SubCategory FLDC = Unknown
Severity Severity 1 (Critical)
LCD Message No LCD message display defined.
153