Reference Guide

Detailed
Description
The communications connnection between OMSS and the Fluid Cache service is
no longer present.
Recommended
Response
Action
To reconnect OMSS to the Fluid Cache service: 1) Verify the Fluid Cache service is
running. To verify the service run the following command: "fldc --status". 2) Re-
establish the connect by running the following command: :"omconfig storage
fluidcache action=connect"
Category Storage
SubCategory FLDC = Unknown
Severity Severity 1 (Critical)
LCD Message No LCD message display defined.
Server
Administrator
Event ID
2699
Server
Administrator
Trap ID
160400
FLDC1029
Message There are not enough journal mirrors available for Fluid Cache to operate.
Detailed
Description
The message indicates that there are not enough journal mirrors available for Fluid
Cache to operate. Make sure that there are at least two journal mirrors that are
accessible. Activate either one or more failed cache devices or use the fldc_restore
utility to rebuild the node.
Recommended
Response
Action
Contact your service provider to diagnose the cause and assist in recovery process.
Category Storage
SubCategory FLDC = Unknown
Severity Severity 1 (Critical)
LCD Message No LCD message display defined.
Server
Administrator
Event ID
2703
Server
Administrator
Trap ID
160400
151