Reference Guide

Detailed
Description
Caching was enabled in write-back mode but currently it is operating in write-
through mode because the fluid Cache Pool has one PCIe-SSD.
Recommended
Response
Action
Add another PCIe SSD device to the Fluid Cache Pool to resolve the issue.
Category Storage
SubCategory FLDC = Unknown
Severity Severity 2 (Warning)
LCD Message No LCD message display defined.
Server
Administrator
Event ID
2930
Server
Administrator
Trap ID
120300;150300
FLDC1025
Message Caching was enabled in write-back or write-through mode, it is currently operating
in pass-through mode.
Detailed
Description
Caching was enabled in write-back mode or write through mode, but currently it is
operating in write-through mode because fluid Cache Pool has no PCIe-SSD
device.
Recommended
Response
Action
Add another PCIe SSD device to the Fluid Cache Pool to resolve the issue.
Category Storage
SubCategory FLDC = Unknown
Severity Severity 2 (Warning)
LCD Message No LCD message display defined.
Server
Administrator
Event ID
2931
Server
Administrator
Trap ID
160300
FLDC1026
Message Caching is no longer degraded to write-through mode and is now operating in
write-back mode for Fluid Cache.
149