Reference Guide
Detailed
Description
The controller detected a new enclosure. This is due either to a hot plug of an
enclosure, or a power state change of an enclosure. In addition, this message is
generated if the daisy chain order of the enclosures changes.
Recommended
Response
Action
No response action is required.
Category Storage
SubCategory ENC = Storage Enclosr
Severity Severity 3 (Informational)
LCD Message No LCD message display defined.
Server
Administrator
Event ID
2190
Server
Administrator
Trap ID
75100
ENC100
Message arg1is sending inconsistent reponses to the controller.
Arguments
• arg1 = enclosure name
Detailed
Description
The storage controller is not receiving a consistent response from the enclosure
due to a firmware problem or an incorrect cabling configuration. If the cables are
longer than the specified maximum length, the signals may be degraded.
Recommended
Response
Action
Turn off all the enclosures attached to the system, check if the cable configurations
are correct. and reboot the system. If the problem persists, update the enclosure
firmware to the latest supported version. Download the latest supported version of
the firmware from the service provider. For more information about cable
configuration, see storage enclosure documentation.
Category Storage
SubCategory ENC = Storage Enclosr
Severity Severity 1 (Critical)
LCD Message No LCD message display defined.
Server
Administrator
Event ID
2300
Server
Administrator
Trap ID
85400
129