Reference Guide

arg2 = EMM0 1
arg3 = EMM1 2
Detailed
Description
An unsupported configuration was detected. The SCSI rate of the Enclosure
Management Modules (EMMs) are not the same.
Recommended
Response
Action
Replace one of the EMMs with the matching SCSI rate EMM.
Category Storage
SubCategory ENC = Storage Enclosr
Severity Severity 2 (Warning)
LCD Message No LCD message display defined.
Server
Administrator
Event ID
2173
Server
Administrator
Trap ID
85300
ENC14
Message The number of enclosures connected onarg1has exceeded the maximum limit
supported by the controller.
Arguments
arg1 = controller name
Detailed
Description
There are too many enclosures attached to the controller port. When the
enclosure limit is exceeded, the controller loses contact with all enclosures
attached to the port. This is an unsupported configuration.
Recommended
Response
Action
Remove the extra enclosures. Refer to the storage hardware documentation for
maximum number of enclosures that can be connected.
Category Storage
SubCategory ENC = Storage Enclosr
Severity Severity 1 (Critical)
LCD Message No LCD message display defined.
Server
Administrator
Event ID
2191
Server
Administrator
Trap ID
85400
118