Reference Guide

Severity Severity 1 (Critical)
LCD Message No LCD message display defined.
Server
Administrator
Event ID
2297
Server
Administrator
Trap ID
95400
ENC3
Message arg1is shutdown.
Arguments
arg1 = Enclosure Name
Detailed
Description
The physical disk enclosure is either hotter or cooler than the maximum or
minimum allowable temperature range.
Recommended
Response
Action
Check for factors that may cause overheating or excessive cooling. For example,
verify that the enclosure fan is working. You should also check the thermostat
settings and examine whether the enclosure is located near a heat source. Make
sure the enclosure has enough ventilation and that the room temperature is not
too hot or too cold. Refer to the enclosure documentation for more diagnostic
information.
Category Storage
SubCategory ENC = Storage Enclosr
Severity Severity 1 (Critical)
LCD Message No LCD message display defined.
Server
Administrator
Event ID
2112
Server
Administrator
Trap ID
85400
ENC4
Message arg1firmware mismatch.
Arguments
arg1 = Enclosure Name
Detailed
Description
The firmware on the EMM modules is not the same version. It is required that both
modules have the same version of the firmware. This alert may be caused when
you attempt to insert an EMM module that has a different firmware version than an
existing module.
112