Dell OpenManage Server Administrator Version 7.
Notes, Cautions, and Warnings NOTE: A NOTE indicates important information that helps you make better use of your computer. CAUTION: A CAUTION indicates either potential damage to hardware or loss of data and tells you how to avoid the problem. WARNING: A WARNING indicates a potential for property damage, personal injury, or death. Copyright © 2014 Dell Inc. All rights reserved. This product is protected by U.S. and international copyright and intellectual property laws.
Contents 1 Introduction..............................................................................................................17 2 AMP Event Messages..............................................................................................19 AMP400............................................................................................................................................... 19 AMP401....................................................................................................
BAT1016...............................................................................................................................................38 BAT1017............................................................................................................................................... 39 BAT1018...............................................................................................................................................39 BAT1019.............................................
CTL4.................................................................................................................................................... 62 CTL5.....................................................................................................................................................62 CTL6.................................................................................................................................................... 63 CTL7........................................
CTL48.................................................................................................................................................. 84 CTL49.................................................................................................................................................. 85 CTL50.................................................................................................................................................. 85 CTL51..........................................
CTL214.............................................................................................................................................. 108 CTL215...............................................................................................................................................108 CTL216...............................................................................................................................................109 CTL217...............................................
FAN0020............................................................................................................................................ 131 FAN0021.............................................................................................................................................131 FAN0022............................................................................................................................................ 132 FAN0024.................................................
FLDC1035.......................................................................................................................................... 154 FLDC1036.......................................................................................................................................... 155 FLDC1037...........................................................................................................................................155 FLDC1038...................................................
PDR6.................................................................................................................................................. 178 PDR7...................................................................................................................................................179 PDR8..................................................................................................................................................180 PDR9............................................
PDR49............................................................................................................................................... 202 PDR50............................................................................................................................................... 202 PDR51................................................................................................................................................ 203 PDR52...............................................
PDR213.............................................................................................................................................. 225 PDR214.............................................................................................................................................. 225 PDR215.............................................................................................................................................. 226 16 PSU Event Messages...............................
20 RRDU Event Messages...................................................................................... 247 RRDU0001.........................................................................................................................................247 RRDU0002........................................................................................................................................ 247 RRDU0003.............................................................................................
24 SYS Event Messages........................................................................................... 271 SYS101................................................................................................................................................ 271 SYS102................................................................................................................................................271 SYS103................................................................................
VDR10................................................................................................................................................292 VDR11................................................................................................................................................ 293 VDR12................................................................................................................................................ 293 VDR13..............................................
VDR53................................................................................................................................................ 315 VDR54................................................................................................................................................ 315 VDR55................................................................................................................................................ 316 VDR58.............................................
1 Introduction The Event Message Reference contains the error and event information generated by firmware and other agents that monitor system components. These events might be logged, presented to the user on one of the system management consoles, or both logged and displayed. Each event consists of the following fields: Message ID Message The unique alphanumeric identifier for the event.
Severity 2 Warning Indicates a high-impact problem where a system or component is disrupted but can remain productive and perform business-level operations. Severity 3 Information Indicates a medium-to-low impact problem that involves a partial or noncritical loss of functionality; operations are impaired but can continue to function. LCD Message The event message text that is displayed on the system's LCD. Initial Default Event messages result in event actions such as logging, SNMP or email alerts.
AMP Event Messages 2 AMP400 Message Arguments Thearg1sensor has failed, and the last recorded value by the sensor wasarg2A. • arg1 = sensor name • arg2 = current Detailed Description The current sensor identified in the message has failed. This condition can cause system performance issues and degradation in the moitoring capability of the system. Recommended Response Action Check the Embedded System Management (ESM) Log for any sensor related faults.
Category System Health SubCategory AMP = Amperage Severity Severity 2 (Warning) LCD Message No LCD message display defined. Server Administrator Event ID 5201 Server Administrator Trap ID AMP402 Message Arguments Thearg1sensor returned to a normal state with a value ofarg2A. • arg1 = sensor name • arg2 = current Detailed Description The current sensor identified in the message has returned to a normal state. Recommended Response Action No response action is required.
Detailed Description The current sensor identified in the message is faulty or the current drawn by the system exceeds the warning threshold. This condition can cause system performance issues and degradation in the moitoring capability of the system. Recommended Response Action Verify the Embedded System Management (ESM) Log for any sensor related faults. If there is a failed sensor, replace the system board. For more information, contact your service provider.
AMP405 Message Arguments Thearg1sensor state has changed to a failed state with a value ofarg2A. • arg1 = sensor name • arg2 = current Detailed Description The current sensor identified in the message may be faulty. This condition can cause system performance issues and degradation in the moitoring capability of the system. Recommended Response Action Check the Embedded System Management (ESM) Log for any sensor related faults. If there is a faulty sensor, replace the system board.
ASR Event Messages 3 ASR200 Message Arguments The watchdog timer expired atarg1. • arg1 = day month date hh:mm:ss yyyy Detailed Description The watchdog timer has expired at the date and time identified in the message, because iDRAC did not receive a response within the specified time.
Severity Severity 1 (Critical) LCD Message No LCD message display defined. Server Administrator Event ID 5006 Server Administrator Trap ID ASR202 Message Arguments The watchdog timer turned off the system atarg1. • arg1 = day month date hh:mm:ss yyyy Detailed Description The watchdog timer has turned off the system after the specified time at the date and time identified in the message, because the operating system has crashed or hung.
Recommended Response Action To determine the correct cause of the exception, contact your service provider Category System Health SubCategory ASR = Auto Sys Reset Severity Severity 1 (Critical) LCD Message No LCD message display defined.
BAT Event Messages 4 BAT0001 Message The system board battery is operating normally. Detailed Description None Recommended Response Action No response action is required. Category System Health SubCategory BAT = Battery Event Severity Severity 3 (Informational) LCD Message No LCD message display defined. Server Administrator Event ID 5702 Server Administrator Trap ID 5702 BAT0002 Message The system board battery has failed.
Server Administrator Event ID 57,045,705 Server Administrator Trap ID 5704 BAT0003 Message The system board battery is present. Detailed Description None Recommended Response Action No response action is required. Category System Health SubCategory BAT = Battery Event Severity Severity 3 (Informational) LCD Message No LCD message display defined. Server Administrator Event ID Server Administrator Trap ID BAT0004 Message The system board battery is absent.
Server Administrator Event ID 5700 Server Administrator Trap ID BAT0030 Message The system board battery is reading low. Detailed Description The system battery level is low, and if the input power is disconnected, the system settings will not be preserved. Recommended Response Action Replace the the battery. Category System Health SubCategory BAT = Battery Event Severity Severity 2 (Warning) LCD Message No LCD message display defined.
Server Administrator Event ID 5701 Server Administrator Trap ID BAT1000 Message Arguments Battery onarg1is missing. • arg1 = controller name Detailed Description The controller cannot communicate with the battery. The battery is absent or improperly connected. A battery with a weak or depleted charge may also cause this message. Recommended Response Action Verify that the device is present and then check the cables. See the storage hardware documentation to verify cabling.
SubCategory BAT = Battery Event Severity Severity 3 (Informational) LCD Message No LCD message display defined. Server Administrator Event ID 2175 Server Administrator Trap ID 115100 BAT1002 Message Arguments The battery onarg1learn cycle has started. • arg1 = controller name Detailed Description This alert is provided for informational purposes. Recommended Response Action No response action is required.
Recommended Response Action No response action is required. Category Storage SubCategory BAT = Battery Event Severity Severity 3 (Informational) LCD Message No LCD message display defined. Server Administrator Event ID 2177 Server Administrator Trap ID 115100 BAT1004 Message Arguments The battery onarg1learn cycle has timed out. • arg1 = controller name Detailed Description The controller battery must be fully charged before the learn cycle can begin.
BAT1005 Message Arguments The battery onarg1learn cycle has been postponed. • arg1 = Controller name Detailed Description This alert is provided for informational purposes. Recommended Response Action No response action is required. Category Storage SubCategory BAT = Battery Event Severity Severity 3 (Informational) LCD Message No LCD message display defined.
Server Administrator Event ID 2180 Server Administrator Trap ID 115100 BAT1007 Message Arguments The battery onarg1learn cycle will start inarg2hours. • arg1 = Controller name • arg2 = arg Detailed Description This alert is provided for informational purposes. Recommended Response Action No response action is required. Category Storage SubCategory BAT = Battery Event Severity Severity 3 (Informational) LCD Message No LCD message display defined.
Category Storage SubCategory BAT = Battery Event Severity Severity 2 (Warning) LCD Message No LCD message display defined. Server Administrator Event ID 2188 Server Administrator Trap ID 115300 BAT1009 Message Arguments Write policy onarg1was changed to Write Back. • arg1 = controller name Detailed Description The controller battery health has returned to normal. Recommended Response Action No response action is required.
Recommended Response Action Start a learn cycle on the battery. Category Storage SubCategory BAT = Battery Event Severity Severity 2 (Warning) LCD Message No LCD message display defined. Server Administrator Event ID 2210 Server Administrator Trap ID 115100 BAT1011 Message Arguments Battery onarg1is in warn only mode and requires reconditioning. • arg1 = Controller name Detailed Description This alert is provided for informational purposes.
Detailed Description The battery cannot be recharged further. Recommended Response Action Replace the battery pack. Category Storage SubCategory BAT = Battery Event Severity Severity 2 (Warning) LCD Message No LCD message display defined. Server Administrator Event ID 2213 Server Administrator Trap ID 115300 BAT1014 Message Arguments arg1battery charge in-progress.
Arguments • arg1 = Controller name Detailed Description Diagnostic event for service to determine if there is an ambient temperature problem. Recommended Response Action No response action is required. Category Storage SubCategory BAT = Battery Event Severity Severity 3 (Informational) LCD Message No LCD message display defined. Server Administrator Event ID 2215 Server Administrator Trap ID 115100 BAT1016 Message Arguments Thearg1battery learn mode has changed to Auto.
BAT1017 Message Arguments Thearg1battery learn mode has changed to Warn. • arg1 = Controller name Detailed Description This alert is provided for informational purposes. Recommended Response Action No response action is required. Category Storage SubCategory BAT = Battery Event Severity Severity 3 (Informational) LCD Message No LCD message display defined. Server Administrator Event ID 2217 Server Administrator Trap ID 115100 BAT1018 Message Arguments Battery onarg1is degraded.
Server Administrator Trap ID 115300 BAT1019 Message Arguments Battery onarg1is charging. • arg1 = Controller name Detailed Description This alert is provided for informational purposes. Recommended Response Action No response action is required. Category Storage SubCategory BAT = Battery Event Severity Severity 3 (Informational) LCD Message No LCD message display defined.
Server Administrator Event ID 2248 Server Administrator Trap ID 115100 BAT1021 Message Arguments The charge level for the battery onarg1is below the normal threshold. • arg1 = controller name Detailed Description The controller battery cannot maintain sufficient charge level to function properly or the battery is discharging. Recommended Response Action Check for other events related to the state of the battery. These may help determine the cause of this event.
Severity Severity 3 (Informational) LCD Message No LCD message display defined. Server Administrator Event ID 2105 Server Administrator Trap ID 115100 BAT1023 Message Arguments The charge level for the battery onarg1is within normal limits. • arg1 = controller name Detailed Description The battery health has returned to normal. Recommended Response Action No response action is required.
Category Storage SubCategory BAT = Battery Event Severity Severity 2 (Warning) LCD Message No LCD message display defined. Server Administrator Event ID 2318 Server Administrator Trap ID 115300 BAT1025 Message Arguments arg1is unable to recover cached data from the Battery Backup Unit (BBU). • arg1 = controller name Detailed Description The controller was unable to recover data from the cache. This may indicate data loss has occurred.
Detailed Description The controller has retrieved cached data. Recommended Response Action No response action is required. Category Storage SubCategory BAT = Battery Event Severity Severity 3 (Informational) LCD Message No LCD message display defined. Server Administrator Event ID 2338 Server Administrator Trap ID 115100 BAT1027 Message Arguments The battery onarg1completed a charge cycle. • arg1 = controller name Detailed Description The battery successfully completed a charge cycle.
Arguments • arg1 = controller name Detailed Description The controller battery voltage is low. This may indicate that the battery is no longer protecting the controller cache. Recommended Response Action The battery needs to recharged. Wait 24 hours to see if the charge is restored. Category Storage SubCategory BAT = Battery Event Severity Severity 2 (Warning) LCD Message No LCD message display defined.
BAT1030 Message Arguments Thearg1battery charge level is normal. • arg1 = Controller name Detailed Description This alert is provided for informational purposes. Recommended Response Action No response action is required. Category Storage SubCategory BAT = Battery Event Severity Severity 3 (Informational) LCD Message No LCD message display defined.
Server Administrator Trap ID 115300 BAT1032 Message Arguments The battery temperature onarg1is normal. • arg1 = controller name Detailed Description The battery temperature is within the normal operating range. Recommended Response Action No response action is required. Category Storage SubCategory BAT = Battery Event Severity Severity 3 (Informational) LCD Message No LCD message display defined.
Severity Severity 2 (Warning) LCD Message No LCD message display defined. Server Administrator Event ID 2174 Server Administrator Trap ID 115300 BAT1035 Message Arguments The battery temperature onarg1is above the normal operating temperature. • arg1 = controller name Detailed Description The battery temperature is above normal operating temperature. Recommended Response Action No response action is required.
Category Storage SubCategory BAT = Battery Event Severity Severity 3 (Informational) LCD Message No LCD message display defined.
BIOS Event Messages 5 BIOS101 Message Unable to read or change any of the system BIOS configuration settings. Detailed Description The system configuration data that BIOS exposes to Server Administrator is malformed or not available and Server Administrator is unable to read or change any of the system BIOS configuration setttings. Recommended Response Action Power cycle the system and retry the operation. If the problem persists, reinstall the BIOS firmware Update Package.
Server Administrator Event ID 5002 Server Administrator Trap ID BIOS103 Message A previously scheduled system BIOS update is canceled. Detailed Description A previously scheduled BIOS update job is cancelled. Recommended Response Action No response action is required. Category Audit SubCategory BIOS = BIOS Management Severity Severity 3 (Informational) LCD Message No LCD message display defined.
CPU Event Messages 6 CPU0000 Message Arguments CPUarg1has an internal error (IERR). • arg1 = number Detailed Description System event log and OS logs may indicate that the exception is external to the processor. Recommended Response Action Review System Event Log and Operating System Logs. If the issue persists, contact technical support. Refer to the product documentation to choose a convenient contact method.
SubCategory CPU = Processor Severity Severity 1 (Critical) LCD Message CPU has a thermal trip. Check CPU heat sink Server Administrator Event ID 5604 Server Administrator Trap ID 5604 CPU0005 Message Arguments CPUarg1configuration is unsupported. • arg1 = number Detailed Description System is unable to boot or may run in a degraded state. Recommended Response Action Review product documentation for supported CPU configurations.
Recommended Response Action No response action is required. Category System Health SubCategory CPU = Processor Severity Severity 3 (Informational) LCD Message No LCD message display defined. Server Administrator Event ID 5602 Server Administrator Trap ID 5602 CPU0008 Message Arguments CPUarg1is disabled. • arg1 = number Detailed Description System is unable to boot or may run in a degraded state.
Detailed Description None Recommended Response Action No response action is required. Category System Health SubCategory CPU = Processor Severity Severity 3 (Informational) LCD Message No LCD message display defined. Server Administrator Event ID Server Administrator Trap ID CPU0010 Message Arguments CPUarg1is throttled. • arg1 = number Detailed Description The CPU is throttled due to thermal or power conditions.
Arguments • arg1 = number Detailed Description None. Recommended Response Action Review System Event Log and Operating System Logs. If the issue persists, contact technical support. Refer to the product documentation to choose a convenient contact method. Category System Health SubCategory CPU = Processor Severity Severity 2 (Warning) LCD Message Correctable Machine Check Exception detected on CPU .
CPUA Event Messages 7 CPUA0023 Message Arguments CPUarg1is absent • arg1 = number Detailed Description None Recommended Response Action Verify processor installation. If present, reseat the processor. Category System Health SubCategory CPUA = Proc Absent Severity Severity 1 (Critical) LCD Message CPU is absent.
CTL Event Messages 8 CTL2 Message Arguments arg1rebuild rate has changed. • arg1 = Controller name Detailed Description You have changed the controller rebuild rate. This alert is provided for informational purposes. Recommended Response Action No response action is required. Category Storage SubCategory CTL = Storage Contr Severity Severity 3 (Informational) LCD Message No LCD message display defined.
Severity Severity 3 (Informational) LCD Message No LCD message display defined. Server Administrator Event ID 2143 Server Administrator Trap ID 75100 CTL4 Message Arguments arg1alarm is disabled. • arg1 = Controller name Detailed Description You have disabled the controller alarm. This alert is provided for informational purposes. Recommended Response Action No response action is required.
Category Storage SubCategory CTL = Storage Contr Severity Severity 2 (Warning) LCD Message No LCD message display defined. Server Administrator Event ID 2146 Server Administrator Trap ID 75300 CTL6 Message Arguments Bad block sense error fromarg1 • arg1 = Controller name Detailed Description A portion of a physical disk is damaged. See Receive a "Bad Block" Alert with "Replacement," "Sense," or "Medium" Error for more information.
Recommended Response Action See Receive a "Bad Block" Alert with "Replacement," "Sense," or "Medium" Error for more information. Category Storage SubCategory CTL = Storage Contr Severity Severity 2 (Warning) LCD Message No LCD message display defined. Server Administrator Event ID 2148 Server Administrator Trap ID 75300 CTL8 Message Arguments Bad block extended sense error onarg1. • arg1 = Controller name Detailed Description A portion of a physical disk is damaged.
Detailed Description A portion of a physical disk is damaged. See Receive a "Bad Block" Alert with "Replacement," "Sense," or "Medium" Error for more information. Recommended Response Action See Receive a "Bad Block" Alert with "Replacement," "Sense," or "Medium" Error for more information. Category Storage SubCategory CTL = Storage Contr Severity Severity 2 (Warning) LCD Message No LCD message display defined.
Arguments • arg1 = controller name Detailed Description A user operation to reset the controller configuration was performed. Recommended Response Action No response action is required. Category Storage SubCategory CTL = Storage Contr Severity Severity 3 (Informational) LCD Message No LCD message display defined. Server Administrator Event ID 2157 Server Administrator Trap ID 75100 CTL12 Message Arguments An invalid SAS configuration has been detected onarg1.
CTL13 Message Arguments Thearg1cache has been discarded. • arg1 = Controller name Detailed Description The controller has flushed the cache and all data in the cache has been lost. This may occur when the system has memory or battery problems that cause the controller to distrust the cache. Although user data may have been lost, this alert does not always indicate that relevant or user data has been lost. Recommended Response Action Verify that the battery and memory are functioning properly.
Server Administrator Event ID 2187 Server Administrator Trap ID 75300 CTL16 Message Arguments None of thearg1properties are set. • arg1 = Controller name Detailed Description This alert is provided for informational purposes. Recommended Response Action Re-issue the command. Category Storage SubCategory CTL = Storage Contr Severity Severity 3 (Informational) LCD Message No LCD message display defined.
Severity Severity 3 (Informational) LCD Message No LCD message display defined. Server Administrator Event ID 2222 Server Administrator Trap ID 75100 CTL19 Message Arguments Abort CC on Error, Copyback, and Load Balance has changed forarg1. • arg1 = Controller name Detailed Description This alert is provided for informational purposes. Recommended Response Action Re-issue the command.
Category Storage SubCategory CTL = Storage Contr Severity Severity 3 (Informational) LCD Message No LCD message display defined. Server Administrator Event ID 2224 Server Administrator Trap ID 75100 CTL21 Message Arguments Abort CC on Error and Load Balance has changed forarg1. • arg1 = Controller name Detailed Description This alert is provided for informational purposes. Recommended Response Action Re-issue the command.
Recommended Response Action Re-issue the command. Category Storage SubCategory CTL = Storage Contr Severity Severity 3 (Informational) LCD Message No LCD message display defined. Server Administrator Event ID 2226 Server Administrator Trap ID 75100 CTL23 Message Arguments Copyback and Auto Copyback on Predictive Failure has changed forarg1. • arg1 = Controller name Detailed Description This alert is provided for informational purposes. Recommended Response Action Re-issue the command.
Detailed Description This alert is provided for informational purposes. Recommended Response Action Re-issue the command. Category Storage SubCategory CTL = Storage Contr Severity Severity 3 (Informational) LCD Message No LCD message display defined. Server Administrator Event ID 2229 Server Administrator Trap ID 75100 CTL25 Message Arguments Auto Copyback on Predictive Failure has changed forarg1.
Arguments • arg1 = Controller name Detailed Description This alert is provided for informational purposes. Recommended Response Action Re-issue the command. Category Storage SubCategory CTL = Storage Contr Severity Severity 3 (Informational) LCD Message No LCD message display defined. Server Administrator Event ID 2231 Server Administrator Trap ID 75100 CTL27 Message Arguments Thearg1alarm is silenced.
CTL28 Message Arguments The Background Initialization (BGI) rate has changed forarg1. • arg1 = Controller name Detailed Description This alert is provided for informational purposes. Recommended Response Action No response action is required. Category Storage SubCategory CTL = Storage Contr Severity Severity 3 (Informational) LCD Message No LCD message display defined.
Server Administrator Trap ID 75100 CTL30 Message Arguments The Check Consistency rate has changed forarg1. • arg1 = Controller name Detailed Description This alert is provided for informational purposes. Recommended Response Action No response action is required. Category Storage SubCategory CTL = Storage Contr Severity Severity 3 (Informational) LCD Message No LCD message display defined.
Server Administrator Event ID 2236 Server Administrator Trap ID 75100 CTL32 Message Arguments Abort CC on Error is modified forarg1. • arg1 = Controller name Detailed Description This alert is provided for informational purposes. Recommended Response Action Re-issue the command. Category Storage SubCategory CTL = Storage Contr Severity Severity 3 (Informational) LCD Message No LCD message display defined.
Severity Severity 3 (Informational) LCD Message No LCD message display defined. Server Administrator Event ID 2238 Server Administrator Trap ID 75100 CTL34 Message Arguments A foreign configuration was cleared onarg1. • arg1 = controller name Detailed Description This is the result of a user operation. Recommended Response Action No response action is required.
Category Storage SubCategory CTL = Storage Contr Severity Severity 3 (Informational) LCD Message No LCD message display defined. Server Administrator Event ID 2240 Server Administrator Trap ID 75100 CTL36 Message Arguments The Patrol Read mode has changed forarg1. • arg1 = Controller name Detailed Description This alert is provided for informational purposes. Recommended Response Action No response action is required.
Recommended Response Action No response action is required. Category Storage SubCategory CTL = Storage Contr Severity Severity 3 (Informational) LCD Message No LCD message display defined. Server Administrator Event ID 2242 Server Administrator Trap ID 75100 CTL38 Message Arguments The Patrol Read operation completed forarg1. • arg1 = controller name Detailed Description The patrol read task ended. Recommended Response Action No response action is required.
Detailed Description This alert is provided for informational purposes. Recommended Response Action No response action is required. Category Storage SubCategory CTL = Storage Contr Severity Severity 3 (Informational) LCD Message No LCD message display defined. Server Administrator Event ID 2267 Server Administrator Trap ID 75100 CTL40 Message Arguments Multi-bit ECC error onarg1DIMM.
CTL41 Message Arguments Single-bit ECC error onarg1. • arg1 = Controller name Detailed Description An error involving a single bit has been encountered during a read or write operation. The error correction algorithm has corrected this error. Recommended Response Action No response action is required. Category Storage SubCategory CTL = Storage Contr Severity Severity 2 (Warning) LCD Message No LCD message display defined.
Server Administrator Trap ID 75100 CTL43 Message Arguments Diagnostic messagearg1fromarg2 • arg1 = args • arg2 = Controller name Detailed Description This alert is provided for informational purposes. The text for this alert is generated by the utility that ran the diagnostics and can vary depending on the situation. Recommended Response Action No response action is required.
LCD Message No LCD message display defined. Server Administrator Event ID 2316 Server Administrator Trap ID 75400 CTL45 Message Arguments Single-bit ECC error onarg1. • arg1 = Controller name Detailed Description The Dual In-line Memory Module (DIMM) is beginning to malfunction. Recommended Response Action Replace the Dual In-line Memory Module (DIMM) to avoid data loss or data corruption. The DIMM is a part of the controller battery pack.
SubCategory CTL = Storage Contr Severity Severity 1 (Critical) LCD Message No LCD message display defined. Server Administrator Event ID 2320 Server Administrator Trap ID 75400 CTL47 Message Arguments Single-bit ECC error onarg1. • arg1 = Controller name Detailed Description The Dual In-line Memory Module (DIMM) is malfunctioning. Data loss or data corruption may occur. The DIMM must be replaced immediately. Recommended Response Action Replace the DIMM immediately.
Foreign Configuration for more information. Foreign configuration is seen when a controller is replaced. Recommended Response Action Import or clear the detected foreign configuration using a configuration tool or utility. Category Storage SubCategory CTL = Storage Contr Severity Severity 3 (Informational) LCD Message No LCD message display defined. Server Administrator Event ID 2326 Server Administrator Trap ID 75100 CTL49 Message Arguments The NVRAM has corrupted data onarg1.
Arguments • arg1 = Controller name Detailed Description The NVRAM has corrupt data. The controller is unable to correct the situation. Recommended Response Action Replace the controller. Category Storage SubCategory CTL = Storage Contr Severity Severity 2 (Warning) LCD Message No LCD message display defined.
CTL52 Message Arguments arg1SAS port report:arg2 • arg1 = Controller name • arg2 = args Detailed Description This alert is provided for informational purposes. The text for this alert is generated by the controller and can vary depending on the situation. Recommended Response Action No response action is required. Category Storage SubCategory CTL = Storage Contr Severity Severity 3 (Informational) LCD Message No LCD message display defined.
Server Administrator Trap ID 75100 CTL54 Message Arguments arg1event log:arg2 • arg1 = Controller name • arg2 = args Detailed Description This alert is provided for informational purposes. The text for this alert is generated by the controller and can vary depending on the situation. Recommended Response Action No response action is required. Category Storage SubCategory CTL = Storage Contr Severity Severity 3 (Informational) LCD Message No LCD message display defined.
SubCategory CTL = Storage Contr Severity Severity 2 (Warning) LCD Message No LCD message display defined. Server Administrator Event ID 2335 Server Administrator Trap ID 75300 CTL56 Message Arguments arg1event log:arg2 • arg1 = Controller name • arg2 = args Detailed Description The text for this alert is generated by the controller and can vary depending on the situation. This text is from events in the controller event log that were generated while Storage Management was not running.
Recommended Response Action No response action is required. Category Storage SubCategory CTL = Storage Contr Severity Severity 3 (Informational) LCD Message No LCD message display defined. Server Administrator Event ID 2339 Server Administrator Trap ID 75100 CTL58 Message Arguments arg1SAS SMP communications errorarg2 • arg1 = Controller name • arg2 = args Detailed Description The text for this alert is generated by the firmware and can vary depending on the situation.
CTL59 Message Arguments arg1SAS expander error:arg2 • arg1 = Controller name • arg2 = args Detailed Description There may be a problem with the enclosure. Verify the health of the enclosure and its components. To verify the health of the enclosure, select the enclosure object in the tree view. The Health sub-tab displays a red X or yellow exclamation point for enclosure components that are failed or degraded. See the enclosure documentation for more information.
Severity Severity 3 (Informational) LCD Message No LCD message display defined. Server Administrator Event ID 2360 Server Administrator Trap ID 75100 CTL61 Message Arguments Physical disks found missing from configuration during boot time onarg1. • arg1 = Controller name Detailed Description The controller has detected a change in the storage configuration between since its last shut down.
Recommended Response Action No response action is required. Category Storage SubCategory CTL = Storage Contr Severity Severity 3 (Informational) LCD Message No LCD message display defined. Server Administrator Event ID 2362 Server Administrator Trap ID 75100 CTL63 Message Arguments Previous configuration was found completely missing during time boot onarg1. • arg1 = Controller name Detailed Description The controller is unable to retrieve storage configuration saved during last shut down.
• arg2 = Controller name Detailed Description This alert is provided for informational purposes. Recommended Response Action No response action is required. Category Storage SubCategory CTL = Storage Contr Severity Severity 3 (Informational) LCD Message No LCD message display defined. Server Administrator Event ID 2371 Server Administrator Trap ID 75100 CTL66 Message Arguments Attempted to import Unsupported Virtual Disk type RAIDarg1onarg2.
CTL67 Message Arguments Attempted to import Virtual Disk with missing span onarg1. • arg1 = Controller name Detailed Description This alert is provided for informational purposes. Recommended Response Action No response action is required. Category Storage SubCategory CTL = Storage Contr Severity Severity 3 (Informational) LCD Message No LCD message display defined.
Server Administrator Trap ID 75100 CTL69 Message Arguments Attempted to import virtual disk with outdated physical disk information onarg1. • arg1 = Controller name Detailed Description This alert is provided for informational purposes. Recommended Response Action No response action is required. Category Storage SubCategory CTL = Storage Contr Severity Severity 3 (Informational) LCD Message No LCD message display defined.
Server Administrator Event ID 2377 Server Administrator Trap ID 75100 CTL71 Message Arguments Attempted to import an incompatible Physical Disk onarg1. • arg1 = Controller name Detailed Description This alert is provided for informational purposes. Recommended Response Action No response action is required. Category Storage SubCategory CTL = Storage Contr Severity Severity 3 (Informational) LCD Message No LCD message display defined.
Severity Severity 2 (Warning) LCD Message No LCD message display defined. Server Administrator Event ID 2379 Server Administrator Trap ID 75300 CTL73 Message Arguments Foreign configuration is imported only partially. Some configurations failed to import onarg1. • arg1 = Controller name Detailed Description This alert is provided for informational purposes. Recommended Response Action No response action is required.
Recommended Response Action Check for the existence of a foreign configuration and import if any. Check that enclosures are cabled correctly. Category Storage SubCategory CTL = Storage Contr Severity Severity 2 (Warning) LCD Message No LCD message display defined. Server Administrator Event ID 2258 Server Administrator Trap ID 75300 CTL75 Message Arguments Preserved cache discarded onarg1. • arg1 = controller name Detailed Description The controller cache was discarded by the user.
Detailed Description The controller encountered errors while applying the configuration on the physical disks. The configuration command applied has not taken effect. Recommended Response Action Re-issue the failed configuration command or try with a different set of physical disks. Contact technical support if the problem persists. Category Storage SubCategory CTL = Storage Contr Severity Severity 1 (Critical) LCD Message No LCD message display defined.
CTL201 Message Arguments The current driver versionarg1(arg2) is older than the required driver versionarg3(arg4) forarg5. • arg1 = major verion number • arg2 = minor version number • arg3 = major version number • arg4 = minor version number • arg5 = controller name Detailed Description The controller driver for the identified controller is not a supported version.
SubCategory CTL = Storage Contr Severity Severity 2 (Warning) LCD Message No LCD message display defined. Server Administrator Event ID 2165 Server Administrator Trap ID 75300 CTL203 Message Arguments Abort Check Consistency on Error, Copyback or Auto Copyback on Predictive Failure, and Load Balance values are changed forarg1. • arg1 = controller name Detailed Description The status of the changed attribute values are reported for information purposes.
Recommended Response Action No response action is required. Category Storage SubCategory CTL = Storage Contr Severity Severity 3 (Informational) LCD Message No LCD message display defined. Server Administrator Event ID 2220 Server Administrator Trap ID 75100 CTL205 Message Arguments Auto Copyback on Predictive Failure, Abort Check Consistency on Error, and Load Balance values are changed forarg1.
Arguments • arg1 = controller name Detailed Description The status of the changed attribute values are reported for information purposes. Recommended Response Action No response action is required. Category Storage SubCategory CTL = Storage Contr Severity Severity 3 (Informational) LCD Message No LCD message display defined.
CTL208 Message Arguments Unable to authenticate the entered passphrase for thearg1. • arg1 = controller name Detailed Description Unable to authenticate the entered passphrase. Recommended Response Action Enter the correct passphrase and retry. Category Storage SubCategory CTL = Storage Contr Severity Severity 2 (Warning) LCD Message No LCD message display defined.
Server Administrator Trap ID 75100 CTL210 Message Arguments Disabled persistent hot spare onarg1. • arg1 = controller name Detailed Description The persistent hot spare feature is disabled on the controller identified in the message. Recommended Response Action No response action is required. Category Storage SubCategory CTL = Storage Contr Severity Severity 3 (Informational) LCD Message No LCD message display defined.
LCD Message No LCD message display defined. Server Administrator Event ID 2398 Server Administrator Trap ID 75100 CTL212 Message Arguments The existing encryption key in thearg1is deleted. • arg1 = controller name Detailed Description This alert is generated when the encryption key in the controller is deleted. Recommended Response Action No response action is required.
SubCategory CTL = Storage Contr Severity Severity 3 (Informational) LCD Message No LCD message display defined. Server Administrator Event ID 2407 Server Administrator Trap ID 75100 CTL214 Message Arguments The Local Key Management (LKM) encryption key in thearg1has changed. • arg1 = controller name Detailed Description The Local Key Management (LKM) encryption key in the controller identified in the message has changed. Recommended Response Action No response action is required.
Recommended Response Action Make sure both the cables are securely attached to the enclosure and controller. FOr more information about connecting the cables to the enclosure, see the Cables Attached Correctly section in the PERC Users Guide. Also, make sure both Enclosure Management Modules (EMMs) are healthy. Category Storage SubCategory CTL = Storage Contr Severity Severity 2 (Warning) LCD Message No LCD message display defined.
Detailed Description The redundant path view on the controller identified in the message is cleared. Recommended Response Action No response action is required. Category Storage SubCategory CTL = Storage Contr Severity Severity 3 (Informational) LCD Message No LCD message display defined.
ENC Event Messages 9 ENC1 Message Arguments arg1was inserted. • arg1 = Enclosure Management Module Name Detailed Description An Enclosure Management Module (EMM) has failed is inserted into the enclosure. Recommended Response Action No response action is required. Category Storage SubCategory ENC = Storage Enclosr Severity Severity 3 (Informational) LCD Message No LCD message display defined.
Severity Severity 1 (Critical) LCD Message No LCD message display defined. Server Administrator Event ID 2297 Server Administrator Trap ID 95400 ENC3 Message Arguments arg1is shutdown. • arg1 = Enclosure Name Detailed Description The physical disk enclosure is either hotter or cooler than the maximum or minimum allowable temperature range. Recommended Response Action Check for factors that may cause overheating or excessive cooling. For example, verify that the enclosure fan is working.
Recommended Response Action Download the same version of the firmware to both EMM modules. Category Storage SubCategory ENC = Storage Enclosr Severity Severity 2 (Warning) LCD Message No LCD message display defined. Server Administrator Event ID 2120 Server Administrator Trap ID 85300 ENC5 Message Arguments Redundancy onarg1is degraded • arg1 = Enclosure Name Detailed Description One or more of the enclosure components has failed. For example, a fan or power supply may have failed.
ENC6 Message Arguments Communication timeout onarg1. • arg1 = Enclosure Name Detailed Description The controller is unable to communicate with an enclosure. There are several reasons for communication loss. For example, there may be a bad or loose cable. An unusual amount of I/O may also interrupt communication with the enclosure. In addition, communication loss may be caused by software, hardware, or firmware problems, bad or failed power supplies, and enclosure shutdown.
Severity Severity 3 (Informational) LCD Message No LCD message display defined. Server Administrator Event ID 2138 Server Administrator Trap ID 85100 ENC8 Message Arguments Thearg1alarm was disabled. • arg1 = Enclosure Name Detailed Description You have disabled the enclosure alarm. Recommended Response Action No response action is required. Category Storage SubCategory ENC = Storage Enclosr Severity Severity 3 (Informational) LCD Message No LCD message display defined.
Category Storage SubCategory ENC = Storage Enclosr Severity Severity 3 (Informational) LCD Message No LCD message display defined. Server Administrator Event ID 2151 Server Administrator Trap ID 85100 ENC10 Message Arguments Thearg1asset name was changed. • arg1 = Enclosure Name Detailed Description You have changed the enclosure asset name. This alert is provided for informational purposes. Recommended Response Action No response action is required.
Recommended Response Action Ensure that the service tag was changed under authorized circumstances. Category Storage SubCategory ENC = Storage Enclosr Severity Severity 3 (Informational) LCD Message No LCD message display defined. Server Administrator Event ID 2153 Server Administrator Trap ID 85100 ENC12 Message Arguments Communication resumed onarg1. • arg1 = Enclosure Name Detailed Description Communication with an enclosure has been restored.
• arg2 = EMM0 1 • arg3 = EMM1 2 Detailed Description An unsupported configuration was detected. The SCSI rate of the Enclosure Management Modules (EMMs) are not the same. Recommended Response Action Replace one of the EMMs with the matching SCSI rate EMM. Category Storage SubCategory ENC = Storage Enclosr Severity Severity 2 (Warning) LCD Message No LCD message display defined.
ENC15 Message Arguments An enclosure blink operation has initiated onarg1. • arg1 = Enclosure Name Detailed Description This alert is provided for informational purposes. Recommended Response Action No response action is required. Category Storage SubCategory ENC = Storage Enclosr Severity Severity 3 (Informational) LCD Message No LCD message display defined.
Server Administrator Trap ID 85100 ENC17 Message Arguments An Enclosure Management Module (EMM) has been discovered onarg1. • arg1 = Enclosure Name Detailed Description This alert is provided for informational purposes. Recommended Response Action No response action is required. Category Storage SubCategory ENC = Storage Enclosr Severity Severity 3 (Informational) LCD Message No LCD message display defined.
Server Administrator Event ID 2292 Server Administrator Trap ID 85400 ENC19 Message Arguments arg1has failed. • arg1 = Enclosure Management Module Name Detailed Description An Enclosure Management Module (EMM) has failed. The failure may be caused by a loss of power to the EMM. The EMM self-test may also have identified a failure. There may also be a firmware problem or a multi-bit error. Recommended Response Action Reseat the Enclosure Management Module (EMM).
SubCategory ENC = Storage Enclosr Severity Severity 1 (Critical) LCD Message No LCD message display defined. Server Administrator Event ID 2295 Server Administrator Trap ID 85400 ENC22 Message Arguments Thearg1has a bad sensorarg2. • arg1 = Enclosure Name • arg2 = args Detailed Description The enclosure has a bad sensor. The enclosure sensors monitor the fan speeds, temperature probes, and so on. Recommended Response Action Refer to the storage hardware documentation for more information.
Recommended Response Action Contact the Dell Technical Support at support.dell.com. Category Storage SubCategory ENC = Storage Enclosr Severity Severity 1 (Critical) LCD Message No LCD message display defined. Server Administrator Event ID 2299 Server Administrator Trap ID 85400 ENC24 Message Arguments Communication witharg1is intermittent. • arg1 = enclosure name Detailed Description The controller is not receiving a consistent response from the enclosure.
Arguments • arg1 = enclosure name Detailed Description The enclosure or an enclosure component is in a Failed or Degraded state. Recommended Response Action Verify the health of the enclosure and its components. See the storage hardware documentation for more information. Contact technical support. Category Storage SubCategory ENC = Storage Enclosr Severity Severity 1 (Critical) LCD Message No LCD message display defined.
ENC27 Message Arguments SAS or SATA mixing of physical disks is not supported within thearg1. • arg1 = Enclosure Name Detailed Description The enclosure cannot support both SAS and SATA physical disks. Physical disks may be disabled. This alert is provided for informational purposes. Recommended Response Action No response action is required. Category Storage SubCategory ENC = Storage Enclosr Severity Severity 3 (Informational) LCD Message No LCD message display defined.
LCD Message No LCD message display defined. Server Administrator Event ID 2311 Server Administrator Trap ID 85300 ENC29 Message Arguments arg1temperature has returned to normal. • arg1 = Enclosure Name Detailed Description This alert is provided for informational purposes. Recommended Response Action No response action is required. Category Storage SubCategory ENC = Storage Enclosr Severity Severity 3 (Informational) LCD Message No LCD message display defined.
SubCategory ENC = Storage Enclosr Severity Severity 3 (Informational) LCD Message No LCD message display defined. Server Administrator Event ID 2354 Server Administrator Trap ID 85100 ENC31 Message Arguments Firmware download onarg1has failed. • arg1 = Enclosure Name Detailed Description The system was unable to download firmware to the enclosure. The controller may have lost communication with the enclosure.
Recommended Response Action No response action is required. Category Storage SubCategory ENC = Storage Enclosr Severity Severity 3 (Informational) LCD Message No LCD message display defined. Server Administrator Event ID 2368 Server Administrator Trap ID 85100 ENC33 Message Arguments Redundancy onarg1is normal. • arg1 = Enclosure Name Detailed Description Data redundancy has been restored to an enclosure that previously suffered a loss of redundancy.
Detailed Description The controller detected a new enclosure. This is due either to a hot plug of an enclosure, or a power state change of an enclosure. In addition, this message is generated if the daisy chain order of the enclosures changes. Recommended Response Action No response action is required. Category Storage SubCategory ENC = Storage Enclosr Severity Severity 3 (Informational) LCD Message No LCD message display defined.
FAN Event Messages 10 FAN0020 Message Arguments Thearg1is non-functional. • arg1 = fan name Detailed Description The fan identified in the message has failed or it is not installed correctly. Recommended Response Action Remove and re-install the fan or replace the fan, and open the OMSA Web interface to verify if the fan specified in the message is displayed correctly. If the issue persists, contact your service provider.
Severity Severity 3 (Informational) LCD Message No LCD message display defined. Server Administrator Event ID 5303 Server Administrator Trap ID FAN0022 Message Arguments Thearg1sensor has failed, and the last recorded value by the sensor wasarg2RPM. • arg1 = sensor name • arg2 = fan speed Detailed Description The sensor identified in the message has failed. The sensor may be required for optimal system performance.
Recommended Response Action No response action is required. Category System Health SubCategory FAN = Fan Event Severity Severity 3 (Informational) LCD Message No LCD message display defined. Server Administrator Event ID 5102 Server Administrator Trap ID 5102 FAN0025 Message Arguments Thearg1sensor state has changed to a warning state with a value ofarg2RPM. • arg1 = sensor name • arg2 = fan speed Detailed Description The fan identified in the message is not functioning correctly.
Arguments • arg1 = sensor name • arg2 = fan speed Detailed Description The fan sensor identified in the message indicates that the related fan has exceeded critical RPM thresholds.. Recommended Response Action Remove and re-install the fan, or replace the fan with a new fan. If the issue persists, contact your service provider. Category System Health SubCategory FAN = Fan Event Severity Severity 1 (Critical) LCD Message No LCD message display defined.
FAN0023 Message Arguments Unable to read thearg1sensor value. • arg1 = sensor name Detailed Description The fan sensor identified in the message has failed or the fan has failed. Recommended Response Action Do the following: 1) Remove the old fan, install a new fan and power cycle the system to check if the fan is working properly, 2) Replace the system board if the fan sensor has failed. 3) If the issue persists, contact your service provider.
FLDC Event Messages 11 FLDC1001 Message Arguments The journal mirror at path =arg1is available. • arg1 = World Wide Name Detailed Description The entry in the journal for the device identified in the message with the WWN (World Wide Name) is available. Recommended Response Action No response action is required. Category Storage SubCategory FLDC = Unknown Severity Severity 3 (Informational) LCD Message No LCD message display defined.
Severity Severity 3 (Informational) LCD Message No LCD message display defined. Server Administrator Event ID 2701 Server Administrator Trap ID 160100 FLDC1003 Message Arguments Cache flushing has started for the virtual disk with WWN =arg1and path =arg2. • arg1 = World Wide Name • arg2 = device pathname Detailed Description The cache flushing operation has started for the virtual disk identified in the message. Recommended Response Action No response action is required.
Recommended Response Action No response action is required. Category Storage SubCategory FLDC = Unknown Severity Severity 3 (Informational) LCD Message No LCD message display defined. Server Administrator Event ID 2876 Server Administrator Trap ID 90100 FLDC1006 Message Arguments The cache devicearg1with WWN =arg2and path =arg3is registered.
Arguments • arg1 = physical disk Name • arg2 = World Wide Name • arg3 = device pathname Detailed Description The cache device identified in the message is removed from the Fluid Cache configuration. Recommended Response Action No response action is required. Category Storage SubCategory FLDC = Unknown Severity Severity 3 (Informational) LCD Message No LCD message display defined.
Server Administrator Trap ID 90100 FLDC1009 Message Arguments Caching is being removed for thearg1with WWN =arg2and path =arg3. • arg1 = virtual disk name • arg2 = World Wide Name • arg3 = device pathname Detailed Description Caching is being removed for the virtual disk identified in the message. Recommended Response Action No response action is required. Category Storage SubCategory FLDC = Unknown Severity Severity 3 (Informational) LCD Message No LCD message display defined.
SubCategory FLDC = Unknown Severity Severity 3 (Informational) LCD Message No LCD message display defined. Server Administrator Event ID 2907 Server Administrator Trap ID 120100;150100 FLDC1012 Message Arguments Caching is disabled for thearg1with WWN =arg2and path =arg3. • arg1 = virtual disk name • arg2 = World Wide Name • arg3 = device pathname Detailed Description The operation to disable caching is successful. Caching is disabled for the virtual disk identified in the message.
Detailed Description The cached LUN identified in the message has had a failure to successfully perform a read or write operation. The user application should now be seeing I/O failures when trying to read or write to the Fluid Cache device at the path identified in the message. Recommended Response Action Contact your service provider to diagnose the cause and assist in recovery process.
FLDC1015 Message Arguments Recovery of the cache devicearg1with wwn =arg2and path =arg3is complete. • arg1 = physical disk name • arg2 = World Wide Name • arg3 = device pathnameh Detailed Description The recovery of the cache device identified in the message complete. Recommended Response Action No response action is required. Category Storage SubCategory FLDC = Unknown Severity Severity 3 (Informational) LCD Message No LCD message display defined.
Server Administrator Trap ID 160100 FLDC1017 Message A license has been installed for Fluid Cache. Detailed Description A license has been installed for Fluid Cache. Recommended Response Action No response action is required. Category Storage SubCategory FLDC = Unknown Severity Severity 3 (Informational) LCD Message No LCD message display defined. Server Administrator Event ID 2920 Server Administrator Trap ID 160100 FLDC1018 Message A license has been removed for Fluid Cache.
Server Administrator Trap ID 160100 FLDC1019 Message All cache devices have been found and registered for Fluid Cache. Detailed Description All cache devices have been found and registered for Fluid Cache. Recommended Response Action No response action is required. Category Storage SubCategory FLDC = Unknown Severity Severity 3 (Informational) LCD Message No LCD message display defined.
Server Administrator Event ID 2909 Server Administrator Trap ID 120300;150300 FLDC1021 Message Arguments The journal mirror entry with WWN =arg1is not accessible. • arg1 = World Wide Name Detailed Description The device identified in the message having the journal mirror entry with given WWN (World Wide Name) is not accessible. A portion of an SSD is used for journal content. To assure consistnecy, the journal content is written into two other SSDs. These copies are journal mirrors.
Recommended Response Action To identify the cause of the configuration inconsistency, contact your service provider. Category Storage SubCategory FLDC = Unknown Severity Severity 2 (Warning) LCD Message No LCD message display defined. Server Administrator Event ID 2874 Server Administrator Trap ID 90300 FLDC1023 Message Arguments Fluid Cache is running on an evaluation license and the evaluation license expires inarg1days.
Detailed Description Caching was enabled in write-back mode but currently it is operating in writethrough mode because the fluid Cache Pool has one PCIe-SSD. Recommended Response Action Add another PCIe SSD device to the Fluid Cache Pool to resolve the issue. Category Storage SubCategory FLDC = Unknown Severity Severity 2 (Warning) LCD Message No LCD message display defined.
Detailed Description The caching mode has been restored back to write-back mode due to the availability of additional PCIeSSD devices in the Fluid Cache configuration. Recommended Response Action No response action is required. Category Storage SubCategory FLDC = Unknown Severity Severity 2 (Warning) LCD Message No LCD message display defined.
Detailed Description The communications connnection between OMSS and the Fluid Cache service is no longer present. Recommended Response Action To reconnect OMSS to the Fluid Cache service: 1) Verify the Fluid Cache service is running. To verify the service run the following command: "fldc --status".
FLDC1030 Message The cluster ID in the journal does not match the cluster ID in the configuration file for Fluid Cache. Detailed Description An Inconsistency was found in Fluid Cache configuration data. Recommended Response Action Service is required. Contact your service provider. Category Storage SubCategory FLDC = Unknown Severity Severity 1 (Critical) LCD Message No LCD message display defined.
FLDC1032 Message Arguments The cache device with WWN =arg1and path =arg2is no longer functional. • arg1 = wwn name • arg2 = path name Detailed Description The PCIeSSD cache device identified in the message is no longer functional. Recommended Response Action Replace the non-functional PCIe SSD. Category Storage SubCategory FLDC = Unknown Severity Severity 1 (Critical) LCD Message No LCD message display defined.
Server Administrator Event ID 2901 Server Administrator Trap ID 120400;150400 FLDC1034 Message A valid license is not installed for Fluid Cache. Detailed Description A valid license is not installed for Fluid Cache. Recommended Response Action Install a valid Fluid Cache license. For more information, contact your service provider. Category Storage SubCategory FLDC = Unknown Severity Severity 1 (Critical) LCD Message No LCD message display defined.
Severity Severity 1 (Critical) LCD Message No LCD message display defined. Server Administrator Event ID 2917 Server Administrator Trap ID 160400 FLDC1036 Message Arguments Caching functionality is disabled because Fluid cache is running on an expired evaluation license (Expired days:arg1). • arg1 = number of days Detailed Description Caching functionality is disabled because Fluid cache is running on an expired evaluation license.
Recommended Response Action Install a permanent Fluid Cache license. Category Storage SubCategory FLDC = Unknown Severity Severity 1 (Critical) LCD Message No LCD message display defined. Server Administrator Event ID 2919 Server Administrator Trap ID 160400 FLDC1038 Message There is not enough memory capacity to run necessary services for Fluid Cache. Detailed Description There is not enough memory capacity to run necessary services for Fluid Cache.
Recommended Response Action Insert the missing cache device. If the cache device was unplugged, reactivate it. Reactivate a cache device by running the following command: "omconfig storage pciessd action=reactivate subsystem=id pciedevice=" Category Storage SubCategory FLDC = Unknown Severity Severity 1 (Critical) LCD Message No LCD message display defined.
HWC Event Messages 12 HWC8000 Message Arguments Unknown device plug event occurred at this location:arg1. Additional Details:arg2. • arg1 = device location • arg2 = details Detailed Description An unknown device plug event occurred at the identified device location. Along with the device location, additional event details are provided if available. Recommended Response Action No response action is required.
Category Audit SubCategory HWC = Hardware Config Severity Severity 3 (Informational) LCD Message No LCD message display defined. Server Administrator Event ID 5651 Server Administrator Trap ID 5651 HWC8002 Message Arguments The device was removed from the system at this location:arg1. Additional Details:arg2. • arg1 = device location • arg2 = details Detailed Description A device was was removed from the system at the location identified in the message.
• arg2 = details Detailed Description A configuration error was detected for a pluggable device installed at the location identified in the message. The device may not be installed correctly. Recommended Response Action Reinsert the device or try inserting a different device of the same type and retry the operation. If the issue persists, check the system documentation to make sure the device is supported or contact your service provider.
Server Administrator Trap ID HWC8005 Message Arguments The SD card device has returned to normal state. SD card location:arg1, SD card device type:arg2, SD card state:arg3. • arg1 = location • arg2 = type • arg3 = state Detailed Description The SD card device has returned to a normal state. The SD card type and the current status of the SD card is also displayed. Recommended Response Action No response action is required.
embedded on the system board, replace the system board. . For more information, contact your service provider. Category System Health SubCategory HWC = Hardware Config Severity Severity 2 (Warning) LCD Message No LCD message display defined. Server Administrator Event ID 5753 Server Administrator Trap ID 5753 HWC8007 Message Arguments The SD card has failed. SD card location:arg1, SD card device type:arg2, SD card state:arg3.
Arguments • arg1 = location • arg2 = type • arg3 = state Detailed Description An SD card device sensor has detected an irrecoverable error in the SD card. Recommended Response Action Replace the old SD card with a new SD card. Category System Health SubCategory HWC = Hardware Config Severity Severity 1 (Critical) LCD Message No LCD message display defined. Server Administrator Event ID 5755 Server Administrator Trap ID HWC8009 Message Arguments SD card device sensor value unknown.
Server Administrator Trap ID 165
LOG Event Messages 13 LOG320 Message Arguments Log monitoring is disabled. Log type:arg1. • arg1 = log type Detailed Description The hardware log in the system is disabled. The log type information is provided. Recommended Response Action No response action is required. Category Audit SubCategory LOG = Log event Severity Severity 2 (Warning) LCD Message No LCD message display defined.
Severity Severity 3 (Informational) LCD Message No LCD message display defined. Server Administrator Event ID 5551 Server Administrator Trap ID LOG322 Message Arguments The log size is no longer near the maximum capacity. Log type:arg1. • arg1 = log type Detailed Description The hardware log in the system is no longer near its maximum capacity. The log type information is provided. Recommended Response Action No response action is required.
Category System Health SubCategory LOG = Log event Severity Severity 2 (Warning) LCD Message No LCD message display defined. Server Administrator Event ID 5553 Server Administrator Trap ID 5553 LOG324 Message Arguments The log size has reached its maximum capacity. Log type:arg1. • arg1 = log type Detailed Description The size of a hardware log in the system has reached its maximum capacity. The log type information is provided.
Recommended Response Action Make sure that iDRAC is functioning correctly. Category System Health SubCategory LOG = Log event Severity Severity 1 (Critical) LCD Message No LCD message display defined. Server Administrator Event ID 5555 Server Administrator Trap ID LOG326 Message The Alert Log was cleared. Detailed Description The Alert Log was cleared. Recommended Response Action No response action is required.
Recommended Response Action No response action is required. Category Audit SubCategory LOG = Log event Severity Severity 3 (Informational) LCD Message No LCD message display defined. Server Administrator Event ID Server Administrator Trap ID LOG328 Message The Server Based Management Mode is enabled. Detailed Description The Server Based Management Mode is enabled. Chassis based PSUs, fans, and sensor information can be displayed from server based system management tools.
Recommended Response Action No response action is required. Category Audit SubCategory LOG = Log event Severity Severity 3 (Informational) LCD Message No LCD message display defined.
MEM Event Messages 14 MEM6000 Message Memory device monitoring is disabled. Detailed Description The memory module may not be correctly seated, wrongly configured, or has failed. Recommended Response Action Review the Embedded System Management (ESM) Log for memory exceptions. Reinstall the memory modules. Category System Health SubCategory MEM = Memory Severity Severity 3 (Informational) LCD Message No LCD message display defined.
Severity Severity 2 (Warning) LCD Message No LCD message display defined. Server Administrator Event ID 5401 Server Administrator Trap ID MEM6002 Message Arguments Memory device status is normal. Memory device location:arg1. • arg1 = location Detailed Description The memory device identified in the message has returned to a normal state. Recommended Response Action No response action is required.
Recommended Response Action Review the Embedded System Management (ESM) Log for memory exceptions. Reinstall the memory modules at the identified location . Category System Health SubCategory MEM = Memory Severity Severity 2 (Warning) LCD Message No LCD message display defined. Server Administrator Event ID 5403 Server Administrator Trap ID 5403 MEM6004 Message Arguments Memory device status is critical. Memory device location:arg1, Possible memory module event cause:arg2.
Arguments • arg1 = location • arg2 = cause Detailed Description The memory module failed because of an irrecoverable error. Recommended Response Action Review the Embedded System Management (ESM) Log for memory exceptions. Remove the old memory module and install a new memory module at the identified location . Category System Health SubCategory MEM = Memory Severity Severity 1 (Critical) LCD Message No LCD message display defined.
PDR Event Messages 15 PDR1 Message Arguments arg1copyback stopped for rebuild. • arg1 = physical disk Detailed Description This message is generated after a copyback stops on a physical disk during a rebuild operation. Recommended Response Action Wait for rebuild to finish, then copyback should resume. Category Storage SubCategory PDR = Physical Disk Severity Severity 2 (Warning) LCD Message No LCD message display defined.
Severity Severity 2 (Warning) LCD Message No LCD message display defined. Server Administrator Event ID 2198 Server Administrator Trap ID 90300 PDR5 Message Arguments arg1is removed. • arg1 = PD Name Detailed Description A physical disk has been removed from the disk group. This alert can also be caused by loose or defective cables or by problems with the enclosure.
Detailed Description A physical disk in the virtual disk is offline. This may have been user initiated. Recommended Response Action Force the physical disk online or assign a hot spare to the virtual disk. Category Storage SubCategory PDR = Physical Disk Severity Severity 2 (Warning) LCD Message No LCD message display defined. Server Administrator Event ID 2050 Server Administrator Trap ID 90300 PDR7 Message Arguments arg1has degraded.
PDR8 Message Arguments arg1is inserted. • arg1 = PD Name Detailed Description This alert is provided for informational purposes. Recommended Response Action No response action is required. Category Storage SubCategory PDR = Physical Disk Severity Severity 3 (Informational) LCD Message No LCD message display defined. Server Administrator Event ID 2052 Server Administrator Trap ID 90100 PDR9 Message Arguments Initialization has started onarg1.
Server Administrator Trap ID 90100 PDR10 Message Arguments arg1rebuild has started. • arg1 = physical disk Detailed Description This message is generated after a rebuild starts on a physical disk. Recommended Response Action No response action is required. Category Storage SubCategory PDR = Physical Disk Severity Severity 3 (Informational) LCD Message No LCD message display defined.
Server Administrator Event ID 2074 Server Administrator Trap ID 90100 PDR12 Message Arguments arg1initialization has failed. • arg1 = PD Name Detailed Description The physical disk has failed or is corrupt. Recommended Response Action Replace the failed or corrupt disk. Identify a disk that has failed by locating the disk that has a red "X" for its status. Restart the initialization.
Severity Severity 1 (Critical) LCD Message No LCD message display defined. Server Administrator Event ID 2083 Server Administrator Trap ID 90400 PDR14 Message Arguments arg1initialization is complete. • arg1 = PD Name Detailed Description This alert is provided for informational purposes. Recommended Response Action No response action is required. Category Storage SubCategory PDR = Physical Disk Severity Severity 3 (Informational) LCD Message No LCD message display defined.
Category Storage SubCategory PDR = Physical Disk Severity Severity 3 (Informational) LCD Message No LCD message display defined. Server Administrator Event ID 2092 Server Administrator Trap ID 90100 PDR16 Message Arguments Predictive failure reported forarg1. • arg1 = physical disk Detailed Description The physical disk is predicted to fail. Many physical disks contain Self Monitoring Analysis and Reporting Technology (SMART).
Detailed Description A user has have assigned a physical disk as a global hot spare. This alert is provided for informational purposes. Recommended Response Action No response action is required. Category Storage SubCategory PDR = Physical Disk Severity Severity 3 (Informational) LCD Message No LCD message display defined. Server Administrator Event ID 2098 Server Administrator Trap ID 90100 PDR18 Message Arguments Global hot spare unassigned fromarg1.
PDR19 Message Arguments SMART FPT exceeded forarg1. • arg1 = PD Name Detailed Description A disk on the specified controller has received a SMART alert (predictive failure) indicating that the disk is likely to fail in the near future. Recommended Response Action Replace the disk that has received the SMART alert. If the physical disk is a member of a non-redundant virtual disk, then back up the data before replacing the disk.
Server Administrator Event ID 2107 Server Administrator Trap ID 90400 PDR21 Message Arguments SMART warning forarg1 • arg1 = PD Name Detailed Description A disk has received a SMART alert (predictive failure). The disk is likely to fail in the near future. Recommended Response Action Replace the disk that has received the SMART alert. If the physical disk is a member of a non-redundant virtual disk, then back up the data before replacing the disk.
is not too hot. Refer to the enclosure documentation for more diagnostic information. 4) If you cannot identify why the disk has reached an unacceptable temperature, then replace the disk. If the physical disk is a member of a nonredundant virtual disk, then back up the data before replacing the disk. Removing a physical disk that is included in a non-redundant virtual disk causes the virtual disk to fail and may cause data loss.
PDR24 Message Arguments Failure prediction threshold exceeded onarg1due to test. No action needed. • arg1 = PD Name Detailed Description A disk has received a SMART alert (predictive failure) due to test conditions. Recommended Response Action No response action is required. Category Storage SubCategory PDR = Physical Disk Severity Severity 2 (Warning) LCD Message No LCD message display defined.
Server Administrator Trap ID 90100 PDR26 Message Arguments arg1is online. • arg1 = physical disk Detailed Description A drive has entered the online state. This may be because the system just started or could be because a problem with the drive has been corrected. Recommended Response Action No response action is required. Category Storage SubCategory PDR = Physical Disk Severity Severity 3 (Informational) LCD Message No LCD message display defined.
Server Administrator Event ID 2160 Server Administrator Trap ID 90100 PDR28 Message Arguments Dedicated hot spare unassigned fromarg1. • arg1 = PD Name Detailed Description A physical disk that was assigned as a hot spare has been unassigned and is no longer functioning as a hot spare. The physical disk was unassigned by a user or automatically unassigned by Storage Management. Storage Management unassigns hot spares that have been used to rebuild data.
Recommended Response Action See A Rebuild Completes with Errors for more information. Category Storage SubCategory PDR = Physical Disk Severity Severity 1 (Critical) LCD Message No LCD message display defined. Server Administrator Event ID 2163 Server Administrator Trap ID 90400 PDR30 Message Arguments A global hot spare failed.arg1 • arg1 = PD Name Detailed Description The controller cannot to communicate with a disk that is assigned as a global hot spare.
Arguments • arg1 = PD Name Detailed Description The controller cannot to communicate with a disk that is assigned as a global hot spare. The disk either failed or was removed. There may also be a bad or loose cable. Recommended Response Action Verify that the disk is healthy and installed. Check the cables. Refer to the product documentation and see the Cables Attached Correctly section for more information on checking the cables. If necessary, replace the disk and reassign the global hot spare.
Server Administrator Trap ID 90300 PDR33 Message Arguments A dedicated hot spare has been removed.arg1 • arg1 = PD Name Detailed Description The controller cannot to communicate with a disk that is assigned as a global hot spare. The disk either failed or was removed. There may also be a bad or loose cable. Recommended Response Action Verify that the disk is healthy and installed. Check the cables.
LCD Message No LCD message display defined. Server Administrator Event ID 2205 Server Administrator Trap ID 90100 PDR35 Message Arguments The only hot spare available is a SATA diskarg1. • arg1 = PD Name Detailed Description The only physical disk available to be assigned as a hot spare is using SATA technology. The physical disks in the virtual disk are using SAS technology.
Recommended Response Action Add a SATA disk that is large enough to be used as the hot spare and assign the new disk as a hot spare. Category Storage SubCategory PDR = Physical Disk Severity Severity 2 (Warning) LCD Message No LCD message display defined. Server Administrator Event ID 2207 Server Administrator Trap ID 90300 PDR37 Message Arguments Thearg1is not supported.
Detailed Description A user has initiated a clear operation on a physical disk. Recommended Response Action No response action is required. Category Storage SubCategory PDR = Physical Disk Severity Severity 3 (Informational) LCD Message No LCD message display defined. Server Administrator Event ID 2249 Server Administrator Trap ID 90100 PDR39 Message Arguments A blink operation has initiated onarg1.
Arguments • arg1 = physical disk Detailed Description This alert is provided for informational purposes. Recommended Response Action No response action is required. Category Storage SubCategory PDR = Physical Disk Severity Severity 3 (Informational) LCD Message No LCD message display defined. Server Administrator Event ID 2252;2438 Server Administrator Trap ID 90100 PDR41 Message Arguments The clear operation onarg1was cancelled.
PDR42 Message Arguments arg1has been started. • arg1 = physical disk Detailed Description This alert is provided for informational purposes. Recommended Response Action No response action is required. Category Storage SubCategory PDR = Physical Disk Severity Severity 3 (Informational) LCD Message No LCD message display defined. Server Administrator Event ID 2255 Server Administrator Trap ID 90100 PDR43 Message Arguments The clear operation onarg1has completed.
Server Administrator Trap ID 90100 PDR44 Message Arguments The clear operation onarg1failed. • arg1 = physical disk Detailed Description A Clear task was being performed on a physical disk but the task was interrupted and did not complete successfully. The controller may have lost communication with the disk, the disk was removed, or the cables may be loose or defective. Recommended Response Action Verify that the disk is present and not in a Failed state. Make sure the cables are attached securely.
Server Administrator Event ID 2272 Server Administrator Trap ID 90400 PDR47 Message Arguments A block onarg1was punctured by the controller. • arg1 = physical disk Detailed Description The controller encountered an unrecoverable medium error when attempting to read a block on the physical disk and marked that block as invalid.
Category Storage SubCategory PDR = Physical Disk Severity Severity 3 (Informational) LCD Message No LCD message display defined. Server Administrator Event ID 2274 Server Administrator Trap ID 90100 PDR49 Message Arguments The dedicated hot sparearg1is too small. • arg1 = PD Name Detailed Description The dedicated hot spare is not large enough to protect all virtual disks that reside on the disk group. Recommended Response Action Assign a larger disk as the dedicated hot spare.
Recommended Response Action Assign a larger disk as the global hot spare. Category Storage SubCategory PDR = Physical Disk Severity Severity 2 (Warning) LCD Message No LCD message display defined. Server Administrator Event ID 2277 Server Administrator Trap ID 90300 PDR51 Message Arguments Hot sparearg1SMART polling has failed.
Detailed Description The controller has two connectors that are connected to the same enclosure. The communication path on one connector has lost connection with the enclosure. The communication path on the other connector is reporting this loss. Recommended Response Action Make sure the cables are attached securely. See the Cables Attached Correctly section for more information on checking the cables. Make sure both Enclosure Management Modules (EMMs) are healthy.
PDR54 Message Arguments A disk media error onarg1was corrected during recovery. • arg1 = physical disk Detailed Description This message is generated after a disk media error is corrected on a physical disk. Recommended Response Action No response action is required. Category Storage SubCategory PDR = Physical Disk Severity Severity 3 (Informational) LCD Message No LCD message display defined.
Server Administrator Trap ID 90300 PDR56 Message Arguments Bad block table onarg1is 80% full. • arg1 = physical disk Detailed Description The bad block table is the table used for remapping bad disk blocks. This table fills as bad disk blocks are remapped. When the table is full, bad disk blocks are no longer remapped, which means that disk errors are no longer corrected. At this point, data loss can occur. The bad block table is now 80 percent full.
SubCategory PDR = Physical Disk Severity Severity 1 (Critical) LCD Message No LCD message display defined. Server Administrator Event ID 2307 Server Administrator Trap ID 90400 PDR58 Message Arguments arg1is incompatible. • arg1 = PD Name Detailed Description A user attempted to replace a disk with another disk that is using an incompatible technology. For example, replaced one side of a mirror with a SAS disk when the other side of the mirror is using SATA technology.
Recommended Response Action Monitor the disk for other messages or indications of poor health. Category Storage SubCategory PDR = Physical Disk Severity Severity 3 (Informational) LCD Message No LCD message display defined. Server Administrator Event ID 2331 Server Administrator Trap ID 90100 PDR60 Message Arguments Error occurred onarg1:arg2. • arg1 = physical disk • arg2 = error code Detailed Description The reason for the error can vary depending on the situation.
Arguments • arg1 = physical disk Detailed Description It is not possible to rebuild data that resides on a defective disk. Recommended Response Action Replace the source disk and restore data from backup. Category Storage SubCategory PDR = Physical Disk Severity Severity 1 (Critical) LCD Message No LCD message display defined. Server Administrator Event ID 2347 Server Administrator Trap ID 90400 PDR62 Message Arguments The rebuild failed due to errors on the targetarg1.
PDR63 Message Arguments A bad disk block onarg1cannot be reassigned during a write operation. • arg1 = physical disk Detailed Description A write operation cannot complete because the disk contains bad disk blocks that could not be reassigned. Data loss may have occurred. Data redundancy may be lost. Recommended Response Action Replace the disk. Category Storage SubCategory PDR = Physical Disk Severity Severity 1 (Critical) LCD Message No LCD message display defined.
Server Administrator Trap ID 90400 PDR65 Message Arguments arg1is marked as missing. • arg1 = physical disk Detailed Description This alert is provided for informational purposes. Recommended Response Action No response action is required. Category Storage SubCategory PDR = Physical Disk Severity Severity 3 (Informational) LCD Message No LCD message display defined.
Server Administrator Event ID 2352 Server Administrator Trap ID 90100 PDR68 Message Arguments Dedicated sparearg1imported as global due to missing disk groups. • arg1 = PD Name Detailed Description This alert is provided for informational purposes Recommended Response Action No response action is required. Category Storage SubCategory PDR = Physical Disk Severity Severity 3 (Informational) LCD Message No LCD message display defined.
Severity Severity 2 (Warning) LCD Message No LCD message display defined. Server Administrator Event ID 2367 Server Administrator Trap ID 90300 PDR70 Message Arguments Copyback started fromarg1toarg2. • arg1 = physical disk • arg2 = physical disk Detailed Description A copyback operation began to copy data from one physical disk to another physical disk. This may be due to a user initiated operation or a predictive failure. Recommended Response Action No response action is required.
Recommended Response Action No response action is required. Category Storage SubCategory PDR = Physical Disk Severity Severity 3 (Informational) LCD Message No LCD message display defined. Server Administrator Event ID 2075 Server Administrator Trap ID 120100 PDR72 Message Arguments Copyback resumed onarg1fromarg2.
Arguments • arg1 = physical disk Detailed Description A user cancelled the copyback operation. Recommended Response Action No response action is required. Category Storage SubCategory PDR = Physical Disk Severity Severity 3 (Informational) LCD Message No LCD message display defined. Server Administrator Event ID 2184 Server Administrator Trap ID 90100 PDR75 Message Arguments Copyback stopped for hot sparearg1.
PDR76 Message Copyback not possible as SAS or SATA mixing is not supported. Detailed Description Copyback not possible as SAS or SATA mixing is not supported in the same virtual disk. This alert is provided for informational purposes. Recommended Response Action No response action is required. Category Storage SubCategory PDR = Physical Disk Severity Severity 2 (Warning) LCD Message No LCD message display defined.
Server Administrator Trap ID PDR98 Message Arguments Command timeout occurred onarg1.arg2. • arg1 = physical disk • arg2 = args Detailed Description An error occurred while performing an action on the disk. Recommended Response Action Check the disk is present or replace the disk. Category Storage SubCategory PDR = Physical Disk Severity Severity 2 (Warning) LCD Message No LCD message display defined.
LCD Message No LCD message display defined. Server Administrator Event ID 2208 Server Administrator Trap ID 90300 PDR101 Message Arguments Global Hot Sparearg1does not cover all arrays. • arg1 = PD Name Detailed Description This alert message occurs if there are arrays not protected with a global hot spare. Recommended Response Action No response action is required. Category Storage SubCategory PDR = Physical Disk Severity Severity 2 (Warning) LCD Message No LCD message display defined.
LCD Message No LCD message display defined. Server Administrator Event ID 2444 Server Administrator Trap ID 90100 PDR103 Message Arguments Cryptographic Erase operation is successfully completed onarg1. • arg1 = physical disk name Detailed Description Cryptographic Erase operation is successfully completed on the physical disk drive identified in the message. Recommended Response Action No response action is required.
SubCategory PDR = Physical Disk Severity Severity 1 (Critical) LCD Message No LCD message display defined. Server Administrator Event ID 2441 Server Administrator Trap ID 90400 PDR110 Message Arguments Thearg1reliability has degraded. • arg1 = PCIe solid state device name Detailed Description The reliability of the PCIe solid state device identified in the message degraded. Data loss is possible.
Recommended Response Action Back up the data on the device, and contact your service provider for further instructions. Category Storage SubCategory PDR = Physical Disk Severity Severity 1 (Critical) LCD Message No LCD message display defined. Server Administrator Event ID 2443 Server Administrator Trap ID 90400 PDR206 Message Arguments arg1is a solid state drive (SSD) that is not supported by the controller.
Detailed Description Unable to assign the physical disk as a dedicated hot spare because the selected disk size does not meet the size requirements of the target Virtual Disk. Recommended Response Action Select a physical disk that matches the size required for the disks used in the target Virtual Disk, and retry the operation. Category Storage SubCategory PDR = Physical Disk Severity Severity 3 (Informational) LCD Message No LCD message display defined.
Arguments • arg1 = physical disk name • arg2 = previous power status • arg3 = current power status Detailed Description The Manage Physical Disk Power feature is enabled for physical drives and the power status of the drives changed. Recommended Response Action No response action is required. Category Storage SubCategory PDR = Physical Disk Severity Severity 3 (Informational) LCD Message No LCD message display defined.
Server Administrator Event ID 2400 Server Administrator Trap ID 90100 PDR211 Message Arguments arg1has encountered storage medium error. • arg1 = physical disk name Detailed Description Storage medium error was detected on the disk identified in the message. Recommended Response Action No response action is required. Category Storage SubCategory PDR = Physical Disk Severity Severity 2 (Warning) LCD Message No LCD message display defined.
Severity Severity 3 (Informational) LCD Message No LCD message display defined. Server Administrator Event ID 2425 Server Administrator Trap ID 90100 PDR213 Message Arguments The state ofarg1changed from Non-RAID to Ready. • arg1 = physical disk name Detailed Description The physical disk state has changed from Non-RAID state to Ready state. Recommended Response Action No response action is required.
Recommended Response Action Replace the physical disk with a supported physical disk that is provided by an authorized hardware provider. Category Storage SubCategory PDR = Physical Disk Severity Severity 2 (Warning) LCD Message No LCD message display defined. Server Administrator Event ID 2359 Server Administrator Trap ID 90300 PDR215 Message Arguments Copyback task toarg1has failed.
PSU Event Messages 16 PSU0001 Message Arguments Power supplyarg1failed. • arg1 = number Detailed Description None Recommended Response Action Remove and re-install the power supply. If the issue persists, contact technical support. Refer to the product documentation to choose a convenient contact method. Category System Health SubCategory PSU = Power Supply Severity Severity 1 (Critical) LCD Message PSU failed.
SubCategory PSU = Power Supply Severity Severity 2 (Warning) LCD Message No LCD message display defined. Server Administrator Event ID 5353 Server Administrator Trap ID 5353 PSU0006 Message Arguments Power supplyarg1is incorrectly configured. • arg1 = number Detailed Description Power supplies should be of the same input type and power rating. Recommended Response Action Install matched power supplies and review product documentation for proper configuration.
Recommended Response Action No response action is required. Category System Health SubCategory PSU = Power Supply Severity Severity 3 (Informational) LCD Message No LCD message display defined. Server Administrator Event ID 5354 Server Administrator Trap ID 5354 PSU0077 Message Arguments Power supplyarg1vendor type mismatch detected. • arg1 = number Detailed Description Power supplies should be of the same input type and power rating.
Detailed Description This power supply revision is not supported for this system. Recommended Response Action Review product documentation, change power supply with correct revision. Category System Health SubCategory PSU = Power Supply Severity Severity 1 (Critical) LCD Message No LCD message display defined. Server Administrator Event ID 5354 Server Administrator Trap ID 5354 PSU100 Message Arguments Power supplyarg1is offline.
PSU101 Message Arguments Power supplyarg1is not present. • arg1 = power supply unit Detailed Description The power supply unit identified in the message is not present, because of the one of the following reasons: 1) The power supply unit is not correctly seated. 2) The power cable may not be connected properly or diconnected. 3) The power supply unit has failed. 4) There is an input power failure.
Server Administrator Event ID 5351 Server Administrator Trap ID PSU0908 Message Arguments Power lost on power unitarg1. • arg1 = number Detailed Description The power supply is installed correctly but an input source is not connected or is not functional. Recommended Response Action Verify the input source is attached to the power supply. Verify the input power is within the operating requirements for the power supply.
SubCategory PSU = Power Supply Severity Severity 1 (Critical) LCD Message No LCD message display defined. Server Administrator Event ID 5354 Server Administrator Trap ID 5354 PSU0914 Message Arguments A predictive failure detected on power unitarg1. • arg1 = number Detailed Description Status from the power supply indicates a power supply exception occurred. The power supply will try to operate. System Performance and power redundancy may be degraded or lost.
Recommended Response Action Reconnect the power cable to the power supply unit if it was disconnected. Restore the input AC power supply. Make sure the power supply is restored to the enclosure from the mains. Category Storage SubCategory PSU = Power Supply Severity Severity 2 (Warning) LCD Message No LCD message display defined.
Detailed Description The enclosure detected that AC power supply was restored to the power supply unit. Recommended Response Action No response action is required. Category Storage SubCategory PSU = Power Supply Severity Severity 3 (Informational) LCD Message No LCD message display defined. Server Administrator Event ID 2325 Server Administrator Trap ID 100100 PSU1050 Message Arguments arg1is switched ON.
PWR Event Messages 17 PWR3000 Message The system is being shut down for thermal protection. Detailed Description To avoid system damage because of insuffecient cooling, the system is being shut down. Recommended Response Action Review the Embedded System Management Log for thermal or environmental failures and warnings, and replace the faulty components. If the issue persists, contact your service provider.
Server Administrator Event ID Server Administrator Trap ID 238 5013
RDU Event Messages 18 RDU0001 Message The fans are redundant. Detailed Description None Recommended Response Action No response action is required. Category System Health SubCategory RDU = Redundancy Severity Severity 3 (Informational) LCD Message No LCD message display defined. Server Administrator Event ID 5304 Server Administrator Trap ID 5304 RDU0002 Message Fan redundancy is lost.
Server Administrator Event ID Server Administrator Trap ID RDU0003 Message Fan redundancy is degraded. Detailed Description One of more fans have failed or have been removed or a configuration change occurred which requires additional fans. Recommended Response Action Remove and re-install failed fans or install additional fans. Category System Health SubCategory RDU = Redundancy Severity Severity 2 (Warning) LCD Message No LCD message display defined.
Server Administrator Event ID 5304 Server Administrator Trap ID 5304 RDU0012 Message Power supply redundancy is lost. Detailed Description The current power operational mode is non-redundant because of a power supply exception, a power supply inventory change, or a system power inventory change. The system was previously operating in a power redundant mode. Recommended Response Action Check the event log for power supply failures. Review system configuration and power consumption.
Server Administrator Event ID 5305 Server Administrator Trap ID 5305 RDU0020 Message Power supply redundancy is disabled. Detailed Description Redundancy is not currently enabled for the power supplies. Recommended Response Action No response action is required. Category System Health SubCategory RDU = Redundancy Severity Severity 3 (Informational) LCD Message No LCD message display defined.
Server Administrator Event ID 5301 Server Administrator Trap ID RDU0022 Message Fan redundancy is disabled. Detailed Description Redundancy is not currently enabled for the fans. Recommended Response Action No response action is required. Category System Health SubCategory RDU = Redundancy Severity Severity 3 (Informational) LCD Message No LCD message display defined.
Server Administrator Event ID Server Administrator Trap ID 244
RFL Event Messages 19 RFL2002 Message Arguments Internal Dual SD Modulearg1is offline. • arg1 = name Detailed Description The SD card module is installed but may be improperly installed or configured incorrectly. Recommended Response Action Reinstall the SD module. Category System Health SubCategory RFL = IDSDM Media Severity Severity 2 (Warning) LCD Message No LCD message display defined.
Severity Severity 1 (Critical) LCD Message Internal Dual SD Module failed.
RRDU Event Messages 20 RRDU0001 Message Internal Dual SD Module is redundant. Detailed Description None Recommended Response Action No response action is required. Category System Health SubCategory RRDU = IDSDM Redundancy Severity Severity 3 (Informational) LCD Message No LCD message display defined. Server Administrator Event ID 5304 Server Administrator Trap ID 5304 RRDU0002 Message Internal Dual SD Module redundancy is lost.
Server Administrator Event ID 5306 Server Administrator Trap ID 5306 RRDU0003 Message Internal Dual SD Module redundancy is degraded. Detailed Description Either one of the SD card or both the SD cards are not functioning properly. Recommended Response Action Replace the failed SD card. Category System Health SubCategory RRDU = IDSDM Redundancy Severity Severity 2 (Warning) LCD Message No LCD message display defined.
Server Administrator Event ID 5302 Server Administrator Trap ID RRDU0011 Message Unable to determine the redundancy status of the Internal SD Module. Detailed Description This occurs because of one of the following reasons: 1) Either one of the SD card or both the SD cards have failed. 2) The Internal SD Module has failed. Recommended Response Action Replace the failed SD card with a new SD card, or replace the Internal SD Module. For more information, contact your service provider.
SEC Event Messages 21 SEC0000 Message The chassis is open. Detailed Description The chassis is open. System performance may be degraded, and security may be compromised. Recommended Response Action Close the chassis. Check system logs. Category System Health SubCategory SEC = Security Event Severity Severity 1 (Critical) LCD Message Intrusion detected. Check chassis cover Server Administrator Event ID 5254 Server Administrator Trap ID 5254 SEC0016 Message The chassis is closed.
Server Administrator Event ID 5252 Server Administrator Trap ID 5252 SEC0051 Message Unable to determine the redundancy status of the chassis intrusion sensor. Detailed Description The chassis may be open. This condition can lead to degraded system performance because of insufficient cooling and the system security may be compromised. Recommended Response Action Close the chassis.
Server Administrator Event ID Server Administrator Trap ID 253
SSD Event Messages 22 SSD1001 Message Arguments Write-cache onarg1is enabled. • arg1 = PCIe SSD name Detailed Description Write-cache is enabled on the PCIe solid state drive (SSD) identified in the message. Recommended Response Action No response action is required. Category Storage SubCategory SSD = PCIe SSD Severity Severity 2 (Warning) LCD Message No LCD message display defined.
Severity Severity 2 (Warning) LCD Message No LCD message display defined. Server Administrator Event ID 2428 Server Administrator Trap ID 90300 SSD1003 Message Arguments arg1is ready for removal. • arg1 = PCIe SSD name Detailed Description The PCIe solid state drive (SSD) identified in the message is ready for removal. Recommended Response Action No response action is required.
Category Storage SubCategory SSD = PCIe SSD Severity Severity 2 (Warning) LCD Message No LCD message display defined. Server Administrator Event ID 2430 Server Administrator Trap ID 90300 SSD1005 Message Arguments Successfully initializedarg1. • arg1 = PCIe SSD name Detailed Description The initialization of the PCIe solid state drive (SSD) identified in the message is complete. Recommended Response Action No response action is required.
Detailed Description The PCIe solid state device identified in the message is approaching the warranted wear-out limit. Recommended Response Action No response action is required. Category Storage SubCategory SSD = PCIe SSD Severity Severity 3 (Informational) LCD Message No LCD message display defined. Server Administrator Event ID 2433 Server Administrator Trap ID 90100 SSD1007 Message Arguments Thearg1has reached or exceeded its warranted wear-out limit.
Arguments • arg1 = PCIe solid state device name Detailed Description The PCIe solid state device identified in the message is between 90% and 100% of reaching read-only mode. Recommended Response Action No response action is required. Category Storage SubCategory SSD = PCIe SSD Severity Severity 3 (Informational) LCD Message No LCD message display defined. Server Administrator Event ID 2435 Server Administrator Trap ID 90100 SSD1009 Message Arguments Thearg1is in read-only mode.
SSD1010 Message Arguments Thearg1is in a security locked state. • arg1 = PCIe solid state device name Detailed Description The PCIe solid state device identified in the message is in a locked state, because an existing initialization task was interrupted due to a power failure or disk removal. Recommended Response Action Run Full Initialize operation on the device identified in the message.
STOR Event Messages 23 STOR1 Message Arguments A devicearg1is in an unknown state. • arg1 = device name Detailed Description The controller cannot communicate with a device. The state of the device cannot be determined. There may be a bad or loose cable, or a missing device, or a problem with the driver or firmware. Recommended Response Action See the storage hardware documentation for information on checking the cables. Check for problems with any enclosures attached to the system.
Recommended Response Action Identify and replace the failed components. To identify the failed component, select the Storage object and click the Health subtab. The controller status displayed on the Health subtab indicates whether a controller has a failed or degraded component. Click the controller that displays a Warning or Failed status. This action displays the controller Health subtab which displays the status of the individual controller components.
STOR0201 Message Unable to determine whether the system has the minimum required versions of the RAID controller drivers and firmware. Detailed Description Unable to determine whether the system has the minimum required versions of the RAID controller drivers. Recommended Response Action See the Readme file on the installation media for driver and firmware requirements.
Server Administrator Event ID 2166 Server Administrator Trap ID 75300 STOR0203 Message The current operating system kernel version and the non-RAID SCSI driver version are older than the minimum required versions. Detailed Description The version of the operating system kernel and the driver do not meet the minimum requirements. Storage Services may not be able to display or perform storage management functions until the system meets the minimum requirements.
Server Administrator Event ID 2168 Server Administrator Trap ID 10300 STOR0205 Message Global rescan initiated for all storage components in the system. Detailed Description A rescan of all storage components in the system is initiated. Recommended Response Action No response action is required. Category Storage SubCategory STOR = Storage Severity Severity 3 (Informational) LCD Message No LCD message display defined.
Server Administrator Event ID 2262 Server Administrator Trap ID 10100 STOR0207 Message Smart thermal shutdown feature is disabled. Detailed Description The storage shutdown feature based on high ambient temperature (smart themal shutdown) is disabled. Recommended Response Action No response action is required. Category Storage SubCategory STOR = Storage Severity Severity 3 (Informational) LCD Message No LCD message display defined.
Server Administrator Event ID 2287 Server Administrator Trap ID 10100 STOR0209 Message Unable to monitor or manage SAS components because the initialization sequence of the devices did not complete. Detailed Description The initialization sequence of SAS components did not complete during system startup. Recommended Response Action Do the following: 1) Make sure that the supported versions of the SAS drivers and firmware are installed. 2) Reboot the system.
Severity Severity 3 (Informational) LCD Message No LCD message display defined. Server Administrator Event ID 2095 Server Administrator Trap ID 75100;85100;90100 STOR0211 Message Arguments Thearg1has returned to normal state. • arg1 = device name Detailed Description The device identified in the message that was previously in an error state has returned to a normal state.
Recommended Response Action Replace the identified device. A failed device is inidicated with a red color "X" status icon. Perform a rescan after replacing the failed device. Category Storage SubCategory STOR = Storage Severity Severity 1 (Critical) LCD Message No LCD message display defined.
SYS Event Messages 24 SYS101 Message Server Administor Data Manager service has started. Detailed Description The Server Administratort Data Manager service has started. Recommended Response Action No response action is required. Category Audit SubCategory SYS = System Info Severity Severity 3 (Informational) LCD Message No LCD message display defined. Server Administrator Event ID 5008 Server Administrator Trap ID SYS102 Message Server Administrator Data Manager service has stopped.
Server Administrator Event ID 5009 Server Administrator Trap ID SYS103 Message Administrator has started. Detailed Description The Server Administrator has started. Recommended Response Action No response action is required. Category Audit SubCategory SYS = System Info Severity Severity 3 (Informational) LCD Message No LCD message display defined. Server Administrator Event ID 5001 Server Administrator Trap ID 5001 SYS104 Message Server Administrator is starting.
Server Administrator Event ID 5000 Server Administrator Trap ID SYS105 Message Arguments Unable to process the event:arg1Date and time of event:arg2. • arg1 = event • arg2 = date time Detailed Description The current software version is unable to process this event because of an internal error. Recommended Response Action Contact your service provider. Category System Health SubCategory SYS = System Info Severity Severity 2 (Warning) LCD Message No LCD message display defined.
LCD Message No LCD message display defined. Server Administrator Event ID 5007 Server Administrator Trap ID SYS107 Message A system reboot was initiated by the user. Detailed Description The user initiated a system reboot. Recommended Response Action No response action is required. Category Audit SubCategory SYS = System Info Severity Severity 3 (Informational) LCD Message No LCD message display defined.
Server Administrator Event ID 5007 Server Administrator Trap ID 5007 SYS109 Message A system power cycle was initiated by the user. Detailed Description The user has initiated a system power cycle action. Recommended Response Action No response action is required. Category Audit SubCategory SYS = System Info Severity Severity 3 (Informational) LCD Message No LCD message display defined.
Server Administrator Event ID 5007 Server Administrator Trap ID 5007 SYS111 Message The actions Shutdown OS First and Power Off System were initiated by the user. Detailed Description The actions will shut down the operating system and then the system. Recommended Response Action No response action is required. Category Audit SubCategory SYS = System Info Severity Severity 3 (Informational) LCD Message No LCD message display defined.
Server Administrator Event ID 5007 Server Administrator Trap ID 5007 SYS113 Message An invalid action was requested by the user. Detailed Description An invalid action was requested by the user. Recommended Response Action No response action is required. Category Audit SubCategory SYS = System Info Severity Severity 3 (Informational) LCD Message No LCD message display defined.
SubCategory SYS = System Info Severity Severity 3 (Informational) LCD Message No LCD message display defined. Server Administrator Event ID 5012 Server Administrator Trap ID SYS115 Message The power cord sensor is non-functional. Detailed Description The power cord sensor becomes non-functional because of one of the following reasons: 1) The power cable may not be connected properly or disconnected. 2) The power cord sensor in the power supply unit has failed.
Recommended Response Action Do of the following to resolve the issue: 1) Reconnect the power cord to the power supply unit. 2) Replace the power supply unit that has the failed power cord sensor, with a new power supply unit. 3) Make sure that the input power supply is restored. Category System Health SubCategory SYS = System Info Severity Severity 2 (Warning) LCD Message No LCD message display defined.
Recommended Response Action Do of the following to resolve the issue: 1) Reconnect the power cord to the power supply unit. 2) Make sure that the input power supply is restored. Category System Health SubCategory SYS = System Info Severity Severity 2 (Warning) LCD Message No LCD message display defined.
TMP Event Messages 25 TMP5 Message Arguments The temperature probe maximum warning value was changed onarg1. • arg1 = Enclosure name Detailed Description You have changed the value for the maximum temperature probe warning threshold. This alert is provided for informational purposes. Recommended Response Action No response action is required. Category Storage SubCategory TMP = Temperature Severity Severity 3 (Informational) LCD Message No LCD message display defined.
Severity Severity 3 (Informational) LCD Message No LCD message display defined. Server Administrator Event ID 2155 Server Administrator Trap ID 105100 TMP500 Message Arguments Thearg1sensor has failed with value thearg2degrees Celsius. • arg1 = sensor name • arg2 = temperature Detailed Description A temperature sensor identified in the message has failed. This condition can cause system performance issues and degradation in the moitoring capability of the system.
Recommended Response Action Verify the Embedded System Management (ESM) Log for any sensor related faults. If there is a failed sensor, replace the system board. For more information, contact your service provider. Category System Health SubCategory TMP = Temperature Severity Severity 2 (Warning) LCD Message No LCD message display defined.
Arguments • arg1 = sensor name • arg2 = temperature Detailed Description The temperature sensor identified in the message is faulty, or the temperature exceeds the warning threshold. This condition can cause system performance issues and degradation in the moitoring capability of the system. Recommended Response Action Verify the Embedded System Management (ESM) Log for any sensor related faults. If there is a failed sensor, replace the system board.
Server Administrator Event ID 5054 Server Administrator Trap ID 5054 TMP505 Message Arguments Thearg1sensor has failed with a value ofarg2degrees Celsius. • • arg1 = sensor name arg2 = temperature Detailed Description The temperature sensor identified in the message has failed. Recommended Response Action Verify the Embedded System Management (ESM) Log for any sensor related faults. If there is a failed sensor, replace the system board. For more information, contact your service provider.
Category Storage SubCategory TMP = Temperature Severity Severity 2 (Warning) LCD Message No LCD message display defined. Server Administrator Event ID 2100 Server Administrator Trap ID 105300 TMP1001 Message Arguments arg1has crossed the minimum warning threshold. • arg1 = tempsensor name Detailed Description The enclosure is too cold. Recommended Response Action Check whether the thermostat setting is too low and whether the room temperature is too cool.
Recommended Response Action Check for factors that may cause overheating. For example, verify that the enclosure fan is working. You should also check the thermostat settings and examine whether the enclosure is located near a heat source. Make sure the enclosure has enough ventilation and that the room temperature is not too hot. Refer to the enclosure documentation for more diagnostic information.
VDR Event Messages 26 VDR4 Message Arguments arg1was created. • arg1 = virtual disk Detailed Description This message is generated after a virtual disk was created on a controller. Recommended Response Action No response action is required. Category Storage SubCategory VDR = Virtual Disk Severity Severity 3 (Informational) LCD Message No LCD message display defined. Server Administrator Event ID 2053 Server Administrator Trap ID 120100 VDR5 Message Arguments arg1was deleted.
SubCategory VDR = Virtual Disk Severity Severity 3 (Informational) LCD Message No LCD message display defined. Server Administrator Event ID 2054 Server Administrator Trap ID 120100 VDR6 Message Arguments arg1configuration has changed. • arg1 = VD Name Detailed Description This alert is provided for informational purposes. Recommended Response Action No response action is required.
Recommended Response Action Create a new virtual disk and restore from a backup. Category Storage SubCategory VDR = Virtual Disk Severity Severity 1 (Critical) LCD Message No LCD message display defined. Server Administrator Event ID 2056 Server Administrator Trap ID 120400 VDR8 Message Arguments arg1has become degraded.
Arguments • arg1 = virtual disk Detailed Description A consistency check operation on a virtual disk has started. Recommended Response Action No response action is required. Category Storage SubCategory VDR = Virtual Disk Severity Severity 3 (Informational) LCD Message No LCD message display defined. Server Administrator Event ID 2058 Server Administrator Trap ID 120100 VDR10 Message Arguments Formatting thearg1has started.
VDR11 Message Arguments arg1has started initializing. • arg1 = virtual disk Detailed Description This message is generated after initialization of a virtual disk starts. Recommended Response Action No response action is required. Category Storage SubCategory VDR = Virtual Disk Severity Severity 3 (Informational) LCD Message No LCD message display defined. Server Administrator Event ID 2061 Server Administrator Trap ID 120100 VDR12 Message Arguments arg1reconfiguration has started.
Server Administrator Trap ID 120100 VDR13 Message Arguments arg1rebuild has started. • arg1 = VD Name Detailed Description This alert is provided for informational purposes. Recommended Response Action No response action is required. Category Storage SubCategory VDR = Virtual Disk Severity Severity 3 (Informational) LCD Message No LCD message display defined.
Server Administrator Event ID 2067 Server Administrator Trap ID 120100 VDR15 Message Arguments Initialization ofarg1was cancelled. • arg1 = virtual disk Detailed Description The initialization operation could not be completed. This may be due to a user action or a physical disk failure. Recommended Response Action If a physical disk failed, then replace the physical disk. Restart the virtual disk initialization.
SubCategory VDR = Virtual Disk Severity Severity 1 (Critical) LCD Message No LCD message display defined. Server Administrator Event ID 2076 Server Administrator Trap ID 120400 VDR17 Message Arguments arg1format failed. • arg1 = VD Name Detailed Description A physical disk included in the virtual disk failed. Recommended Response Action Replace the failed physical disk. Identify the failed physical disk by locating the disk that has a red "X" for its status. Rebuild the physical disk.
Recommended Response Action If a physical disk has failed, replace the physical disk. Restart the virtual disk initialization. Category Storage SubCategory VDR = Virtual Disk Severity Severity 1 (Critical) LCD Message No LCD message display defined. Server Administrator Event ID 2079 Server Administrator Trap ID 120400 VDR19 Message Arguments Reconfiguration ofarg1has failed. • arg1 = virtual disk Detailed Description The reconfiguration operation was not completed.
Detailed Description A physical disk included in the virtual disk has failed or is corrupt. You may also have cancelled the rebuild. Recommended Response Action Replace the failed or corrupt disk. You can identify a disk that has failed by locating the disk that has a red "X" for its status. Restart the virtual disk rebuild. Category Storage SubCategory VDR = Virtual Disk Severity Severity 1 (Critical) LCD Message No LCD message display defined.
Arguments • arg1 = VD Name Detailed Description This alert is provided for informational purposes. Recommended Response Action No response action is required. Category Storage SubCategory VDR = Virtual Disk Severity Severity 3 (Informational) LCD Message No LCD message display defined. Server Administrator Event ID 2086 Server Administrator Trap ID 120100 VDR23 Message Arguments Initialization ofarg1has completed.
VDR24 Message Arguments Reconfiguration ofarg1has completed. • arg1 = virtual disk Detailed Description The re-configuration operation on the virtual disk completed. Recommended Response Action No response action is required. Category Storage SubCategory VDR = Virtual Disk Severity Severity 3 (Informational) LCD Message No LCD message display defined. Server Administrator Event ID 2090 Server Administrator Trap ID 120100 VDR25 Message Arguments arg1rebuild is completed.
Server Administrator Trap ID 120100 VDR26 Message Arguments The check consistency on aarg1has been paused (suspended). • arg1 = VD Name Detailed Description You paused the Check Consistency operation on a virtual disk. Recommended Response Action To resume the Check Consistency operation, right-click the virtual disk in the Storage Management tree view and select Resume Check Consistency.
Server Administrator Event ID 2115 Server Administrator Trap ID 120100 VDR28 Message A virtual disk and its mirror have been split. Detailed Description A user has caused a mirrored virtual disk to be split. When a virtual disk is mirrored, its data is copied to another virtual disk to maintain redundancy. After being split, both virtual disks retain a copy of the data. Because the mirror is no longer intact, updates to the data are no longer copied to the mirror.
LCD Message No LCD message display defined. Server Administrator Event ID 2117 Server Administrator Trap ID 120100 VDR30 Message Arguments arg1write policy has changed. • arg1 = virtual disk Detailed Description A user changed the write policy for a virtual disk. Recommended Response Action This alert is provided for informational purposes. Category Storage SubCategory VDR = Virtual Disk Severity Severity 3 (Informational) LCD Message No LCD message display defined.
Category Storage SubCategory VDR = Virtual Disk Severity Severity 2 (Warning) LCD Message No LCD message display defined. Server Administrator Event ID 2125 Server Administrator Trap ID 120300 VDR32 Message Arguments Background initialization has started forarg1. • arg1 = virtual disk Detailed Description Background initialization of a virtual disk has started. This is an automated process that writes the parity or mirror data on newly created virtual disks.
Recommended Response Action No response action is required. Category Storage SubCategory VDR = Virtual Disk Severity Severity 3 (Informational) LCD Message No LCD message display defined. Server Administrator Event ID 2128 Server Administrator Trap ID 120100 VDR34 Message Arguments Background initialization failed forarg1. • arg1 = virtual disk Detailed Description Background initialization of a virtual disk failed. Recommended Response Action Run a consistency check on the virtual disk.
Detailed Description Background initialization of a virtual disk completed. Recommended Response Action No response action is required. Category Storage SubCategory VDR = Virtual Disk Severity Severity 3 (Informational) LCD Message No LCD message display defined. Server Administrator Event ID 2130 Server Administrator Trap ID 120100 VDR37 Message Arguments Dead disk segments are restored onarg1.
Arguments • arg1 = VD Name Detailed Description A user renamed a virtual disk. This alert is provided for informational purposes. Recommended Response Action No response action is required. Category Storage SubCategory VDR = Virtual Disk Severity Severity 3 (Informational) LCD Message No LCD message display defined. Server Administrator Event ID 2159 Server Administrator Trap ID 120100 VDR39 Message Arguments The check consistency has made corrections and completed forarg1.
VDR40 Message Arguments The reconfiguration ofarg1has resumed. • arg1 = virtual disk Detailed Description This message is generated after the reconfiguration of a virtual disk resumes. Recommended Response Action No response action is required. Category Storage SubCategory VDR = Virtual Disk Severity Severity 3 (Informational) LCD Message No LCD message display defined.
Server Administrator Trap ID 120100 VDR42 Message Arguments Dedicated hot spare assigned physical diskarg1. • arg1 = args Detailed Description This alert is provided for informational purposes. Recommended Response Action No response action is required. Category Storage SubCategory VDR = Virtual Disk Severity Severity 3 (Informational) LCD Message No LCD message display defined.
Server Administrator Event ID 2196 Server Administrator Trap ID 120100 VDR44 Message Arguments arg1disk cache policy has changed. • arg1 = VD Name Detailed Description This alert is provided for informational purposes. Recommended Response Action No response action is required. Category Storage SubCategory VDR = Virtual Disk Severity Severity 3 (Informational) LCD Message No LCD message display defined.
Severity Severity 3 (Informational) LCD Message No LCD message display defined. Server Administrator Event ID 2244 Server Administrator Trap ID 120100 VDR46 Message Arguments arg1blink has ceased. • arg1 = VD Name Detailed Description This alert is provided for informational purposes. Recommended Response Action No response action is required. Category Storage SubCategory VDR = Virtual Disk Severity Severity 3 (Informational) LCD Message No LCD message display defined.
Category Storage SubCategory VDR = Virtual Disk Severity Severity 3 (Informational) LCD Message No LCD message display defined. Server Administrator Event ID 2280 Server Administrator Trap ID 120100 VDR48 Message Arguments arg1has inconsistent data. • arg1 = VD Name Detailed Description This alert is provided for informational purposes. The virtual disk has inconsistent data. This may be caused when a power loss or system shutdown occurs while data is being written to the virtual disk.
physical disk and the target disk with redundant data have failed. A rebuild is not possible because there is no longer redundancy. Recommended Response Action Replace the failed disks and restore from backup. Category Storage SubCategory VDR = Virtual Disk Severity Severity 1 (Critical) LCD Message No LCD message display defined.
VDR51 Message Arguments The consistency check process made corrections and completed onarg1. • arg1 = virtual disk Detailed Description The consistency check completed on the virtual disk after making corrections. Recommended Response Action No response action is required. Category Storage SubCategory VDR = Virtual Disk Severity Severity 3 (Informational) LCD Message No LCD message display defined.
Server Administrator Event ID 2342 Server Administrator Trap ID 120300 VDR53 Message Arguments The consistency check logging of inconsistent parity data is disabled forarg1. • arg1 = virtual disk Detailed Description The consistency check can no longer report errors in the parity data. Recommended Response Action See the storage hardware documentation for more information on consistency check operation. Contact technical support.
Severity Severity 2 (Warning) LCD Message No LCD message display defined. Server Administrator Event ID 2344 Server Administrator Trap ID 120300 VDR55 Message Arguments arg1initialization has failed. • arg1 = VD Name Detailed Description The controller cannot communicate with attached devices. A disk may be removed or contain errors. Cables may also be loose or defective. Recommended Response Action Verify the health of attached devices. Review the Alert Log for significant events.
Recommended Response Action Recovering a physical disk bad block depends on the RAID level and state of the virtual disk. If a virtual disk is redundant, the controller can recover a bad block on a physical disk. If a virtual disk is not redundant, then the physical disk bad block results in a virtual disk bad block. Category Storage SubCategory VDR = Virtual Disk Severity Severity 1 (Critical) LCD Message No LCD message display defined.
Detailed Description This message occurs if there are medium errors in the physical drives. Recommended Response Action Replace the failed drives. Category Storage SubCategory VDR = Virtual Disk Severity Severity 1 (Critical) LCD Message No LCD message display defined. Server Administrator Event ID 2397 Server Administrator Trap ID 120400 VDR93 Message Arguments arg1bad block medium error is cleared.
Arguments • arg1 = virtual disk Detailed Description This message occurs if the controller pinned cache is recovered. Recommended Response Action No response action is required. Category Storage SubCategory VDR = Virtual Disk Severity Severity 3 (Informational) LCD Message No LCD message display defined. Server Administrator Event ID 2381 Server Administrator Trap ID 75100 VDR97 Message Arguments Patrol Read corrected a media error onarg1.
VDR100 Message Arguments arg1is unavailable because of incompatibilities with the current controller. • arg1 = virtual disk Detailed Description The virtual disk identified in message cannot be used because of missing features on the current controller. The features may be missing because they are not available in the firmware version on the controller or the necessary licenses are not installed. Recommended Response Action Update the controller firmware and license to match the peer controller.
Server Administrator Event ID 2383 Server Administrator Trap ID 120100 VDR102 Message Arguments Hot Spare Protection policy deviation with severity set at Warning level occured forarg1. • arg1 = virtual disk names Detailed Description The number of hot spares available for the virtual disks identified in the message are not compliant with Hot Spare Protection policy, whose severity is set at Warning level. Recommended Response Action Make appropriate assignments of hotspares to meet the policy.
Recommended Response Action Make appropriate assignments of hotspares to meet the policy. Category Storage SubCategory VDR = Virtual Disk Severity Severity 1 (Critical) LCD Message No LCD message display defined. Server Administrator Event ID 2385 Server Administrator Trap ID 120400 VDR104 Message Arguments Successfully securedarg1.
Detailed Description Virtual Disk creation using power save mode drives successfully completed and the Virtual Disk identified in the message is ready for use. Recommended Response Action No response action is required. Category Storage SubCategory VDR = Virtual Disk Severity Severity 3 (Informational) LCD Message No LCD message display defined.
VDR107 Message Arguments Successfully resized Controller Enhanced cache (arg1). • arg1 = virtual disk name Detailed Description The Controller Enhanced cache identified in the message was successfully resized. Recommended Response Action No response action is required. Category Storage SubCategory VDR = Virtual Disk Severity Severity 3 (Informational) LCD Message No LCD message display defined.
Server Administrator Trap ID 120100 VDR109 Message Arguments Successfully deleted Controller Enhanced cache (arg1). • arg1 = virtual disk name Detailed Description The Controller Enhanced cache identified in the message was successfully deleted. Recommended Response Action No response action is required. Category Storage SubCategory VDR = Virtual Disk Severity Severity 3 (Informational) LCD Message No LCD message display defined.
Server Administrator Event ID 2417 Server Administrator Trap ID 120400 VDR111 Message Arguments Corrected disk storage medium error onarg1. • arg1 = virtual disk name Detailed Description The controller corrected a disk storage medium error on one of the participating physical disks of the virtual disk identified in the message. Recommended Response Action No response action is required.
Severity Severity 2 (Warning) LCD Message No LCD message display defined.
VLT Event Messages 27 VLT400 Message Arguments Thearg1sensor has failed with a valuearg2Volts. • arg1 = sensor name • arg2 = voltage Detailed Description A voltage sensor identified in the message may have failed. This condition can cause system performance issues and degradation in the moitoring capability of the system. Recommended Response Action Do one of the following to resolve the issue: 1) Verify the Embedded System Management (ESM) Log for any sensor related faults.
Recommended Response Action Do one of the following to resolve the issue: 1) Verify the Embedded System Management (ESM) Log for any sensor related faults. If there is a failed sensor, replace the system board. 2) Re-configure the system to a minimum configuration, and verify if the sensor displays a normal value, otherwise replace the system board. 3) If the sensor identified is a processor voltage sensor, remove the processor module and inspect processor socket, and replace if required.
VLT403 Message Arguments Thearg1sensor state has changed to a warning state with a value ofarg2Volts. • arg1 = sensor name • arg2 = voltage Detailed Description The voltage sensor identified in the message is faulty, or the voltage exceeds the preset warning threshold. This condition can cause system performance issues and degradation in the moitoring capability of the system.
processor module and inspect processor socket, and replace if required. If the issue persists, contact your service provider. Category System Health SubCategory VLT = Voltage Severity Severity 1 (Critical) LCD Message No LCD message display defined. Server Administrator Event ID 5154 Server Administrator Trap ID 5154 VLT405 Message Arguments Thearg1sensor has failed with a value ofarg2Volts.