Reference Guide

SubCategory ASR = Auto Sys Reset
Severity Severity 1 (Critical)
Trap/EventID FALSE
LCD Message No LCD message display defined.
Initial Default. TRUE
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
DONTKN
OW
FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE
ASR202
Message The watchdog timer turned off the system at
arg1
.
Arguments
arg1 =
day month date hh:mm:ss yyyy
Detailed
Description
The watchdog timer has turned off the system after the specified time at the date and time
identified in the message, because the operating system has crashed or hung.
Recommended
Response Action
To determine the correct cause of the exception, contact your service provider
Category System Health
SubCategory ASR = Auto Sys Reset
Severity Severity 1 (Critical)
Trap/EventID FALSE
LCD Message No LCD message display defined.
Initial Default. TRUE
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
DONTKN
OW
FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE
ASR203
Message The watchdog timer performed an AC power cycle on the system at
arg1
.
Arguments
arg1 =
day month date hh:mm:ss yyyy
Detailed
Description
The watchdog timer has performed an AC power cycle on the system after the specified time
at the date and time identified in the message, because the operating system has crashed or
hung.
99