Reference Guide

Recommended
Response Action
If unintended, review system configuration and power consumption and install power supplies
accordingly. Check power supply status for failures.
Category System Health
SubCategory RDU = Redundancy
Severity Severity 3 (Informational)
Trap/EventID 2475
LCD Message No LCD message display defined.
Initial Default. FALSE
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
TRUE TRUE TRUE TRUE TRUE FALSE FALSE FALSE FALSE
RDU0015
Message The power supplies are not redundant. Insufficient resources to maintain normal operations.
Detailed
Description
The system may power down or operate in a performance degraded state.
Recommended
Response Action
Check the event log for power supply failures. Review system configuration and power
consumption and upgrade or install power supplies accordingly.
Category System Health
SubCategory RDU = Redundancy
Severity Severity 1 (Critical)
Trap/EventID 2473
LCD Message PSUs are not redundant. Insufficient resources. Check PSU cables.
Initial Default. FALSE
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
TRUE TRUE TRUE TRUE TRUE FALSE TRUE TRUE TRUE
RDU0020
Message Power supply redundancy is disabled.
Detailed
Description
Redundancy is not currently enabled for the power supplies.
Recommended
Response Action
No response action is required.
Category System Health
955