Reference Guide

SubCategory RAC = RAC Event
Severity Severity 3 (Informational)
Trap/EventID FALSE
LCD Message No LCD message display defined.
Initial Default. FALSE
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
FALSE FALSE FALSE FALSE TRUE FALSE FALSE FALSE FALSE
RAC0711
Message Unknown power on response from the CMC.
Detailed
Description
Unknown power on response from the CMC.
Recommended
Response Action
Try reseting the CMC. Also try reseating the server.
Category Audit
SubCategory RAC = RAC Event
Severity Severity 3 (Informational)
Trap/EventID FALSE
LCD Message No LCD message display defined.
Initial Default. FALSE
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
FALSE FALSE FALSE FALSE TRUE FALSE FALSE FALSE FALSE
RAC0712
Message Server failed to power up due to zero power allocated.
Detailed
Description
Server failed to power up due to zero power allocated.
Recommended
Response Action
Utilize the Chassis Management Controller web interface to check available power and server
power requirements. If sufficient power is available, allocate power necessary and retry the
operation.
Category Audit
SubCategory RAC = RAC Event
Severity Severity 3 (Informational)
943