Reference Guide

Severity Severity 2 (Warning)
Trap/EventID FALSE
LCD Message No LCD message display defined.
Initial Default. FALSE
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE
RAC1020
Message No objects are available under the specified group for the current system configuration.
Detailed
Description
Some objects have dependencies on other objects that are required to perform a task. The
specified group does not contain any objects, because the dependent objects are not part of
the current system configuration.
Recommended
Response Action
Verify the dependencies of the objects under the specified group using "racadm help <device
class>.<groupname>", and retry the operation. For example, "racadm help
NIC.IscsiSecondTgtParams".
Category Configuration
SubCategory RAC = RAC Event
Severity Severity 3 (Informational)
Trap/EventID FALSE
LCD Message No LCD message display defined.
Initial Default. FALSE
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE
RAC1021
Message NIC objects are not available in the current system configuration.
Detailed
Description
NIC objects are not available if NIC devices are not installed in the system, or if some iDRAC
services are busy.
Recommended
Response Action
Make sure the NIC devices are correctly installed in the system and retry the operation after
the Collect System Inventory On Restart (CSIOR) feature has updated the system inventory. If
the issue persists, contact your service provider.
Category Configuration
SubCategory RAC = RAC Event
Severity Severity 2 (Warning)
935