Reference Guide

Detailed
Description
Unable to change the auto-negotiation state for the current NIC selection mode, because the
iDRAC NIC is in dedicated mode.
Recommended
Response Action
Change the iDRAC NIC mode to shared mode using "racadm set idrac.nic.selection <value>",
and retry the operation.
Category Configuration
SubCategory RAC = RAC Event
Severity Severity 2 (Warning)
Trap/EventID FALSE
LCD Message No LCD message display defined.
Initial Default. FALSE
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE
RAC1013
Message The SNMPv3 authentication protocol state cannot be set to None if the SNMPv3 privacy
protocol state is set to None.
Detailed
Description
For any iDRAC user, SNMPv3 authentication protocol can be changed to "None" only if the
SNMPv3 privacy protocol state is set to "None".
Recommended
Response Action
Change the SNMPv3 privacy protocol state to None using "racadm set
iDRAC.Users.<index>.SNMPv3PrivacyType none", and retry the operation.
Category Configuration
SubCategory RAC = RAC Event
Severity Severity 2 (Warning)
Trap/EventID FALSE
LCD Message No LCD message display defined.
Initial Default. FALSE
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE
RAC1014
Message The SNMPv3 privacy protocol cannot be configured to AES or DES mode if SNMPv3
authentication protocol state is set to "None".
Detailed
Description
The SNMPv3 privacy protocol cannot be configured to AES or DES mode if SNMPv3
authentication protocol state is set to "None".
932