Reference Guide
RAC1010
Message Unable to set the power cap value.
Detailed
Description
The power cap cannot be set if the object Power.Cap is disabled.
Recommended
Response Action
Enable Power Cap setting using "racadm set System.Power.Cap.Enable < 1 | Enabled >", and
retry the operation.
Category Configuration
SubCategory RAC = RAC Event
Severity Severity 2 (Warning)
Trap/EventID FALSE
LCD Message No LCD message display defined.
Initial Default. FALSE
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE
RAC1011
Message The OS to iDRAC pass-through cannot be enabled.
Detailed
Description
The OS to iDRAC pass-through cannot be enabled, because the NIC is in Dedicated mode.
Recommended
Response Action
Change the iDRAC NIC mode to shared mode using "racadm set idrac.nic.selection <value>",
and retry the opeation.
Category Configuration
SubCategory RAC = RAC Event
Severity Severity 2 (Warning)
Trap/EventID FALSE
LCD Message No LCD message display defined.
Initial Default. FALSE
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE
RAC1012
Message Unable to change the auto-negotiation state for the current NIC selection mode.