Message Recurrence interval is not applicable for this subcategory.
Detailed
Description
An alert recurrence cannot be set for the specified subcategory. The alert recurrence is
applicable only to the TMPS subcategory.
Recommended
Response Action
1. Check if the alert recurrence is applicable to this subcategory. To check this run racadm
eventfilters get. 2. To set the notifications for the specified subcategory, run the command
without the -r option.
Category Configuration
SubCategory RAC = RAC Event
Severity Severity 3 (Informational)
Trap/EventID FALSE
LCD Message No LCD message display defined.
Initial Default. FALSE
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE
RAC926
Message The recurrence interval needs to be an integer from 0 to 365.
Detailed
Description
The value given for the recurrence interval is invalid. It has to be a value from 0 to 365.
Recommended
Response Action
Change the argument of ?r to a value from 0 to 365 and then run the same command.
Category Configuration
SubCategory RAC = RAC Event
Severity Severity 2 (Warning)
Trap/EventID FALSE
LCD Message No LCD message display defined.
Initial Default. FALSE