Reference Guide

Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
DONTKN
OW
FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE
AMP405
Message The
arg1
sensor state has changed to a failed state with a value of
arg2
A.
Arguments
arg1 =
sensor name
arg2 =
current
Detailed
Description
The current sensor identified in the message may be faulty. This condition can cause system
performance issues and degradation in the moitoring capability of the system.
Recommended
Response Action
Check the Embedded System Management (ESM) Log for any sensor related faults. If there is a
faulty sensor, replace the system board. For more information, contact your service provider.
Category System Health
SubCategory AMP = Amperage
Severity Severity 1 (Critical)
Trap/EventID FALSE
LCD Message No LCD message display defined.
Initial Default. TRUE
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
DONTKN
OW
FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE
AMP404
Message The
arg1
sensor detected an error with a value of
arg2
A.
Arguments
arg1 =
sensor name
arg2 =
current
Detailed
Description
The current sensor identified in the message is faulty or the current drawn by the system
exceed the critical threshold. This condition can cause system performance issues and
degradation in the moitoring capability of the system.
Recommended
Response Action
Review system power policy, check system logs for power related failures, and review system
configuration changes. For more information, contact your service provider.
Category System Health
SubCategory AMP = Amperage
89