Reference Guide

Detailed
Description
The syntax of the specified command is incorrect.
Recommended
Response Action
See the command help text. To see the help text, run "racadm help <subcommand>".
Category Configuration
SubCategory RAC = RAC Event
Severity Severity 3 (Informational)
Trap/EventID FALSE
LCD Message No LCD message display defined.
Initial Default. FALSE
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE
RAC918
Message Unable to get the inlet temperature data.
Detailed
Description
Racadm unable to obtain the inlet temperature data. This happens if there is no data populated
in the temperature tables or if the underlying instrumentation does not return valid values.
Recommended
Response Action
Wait for the underlying instrumentation to populate the thermal tables. Retry the operation.
Category System Health
SubCategory RAC = RAC Event
Severity Severity 3 (Informational)
Trap/EventID FALSE
LCD Message No LCD message display defined.
Initial Default. FALSE
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE
RAC919
Message Copy to remote share unsuccessful. Remote share might be write protected.
Detailed
Description
Racadm could not export the inlet temperature history file to the specified remote share. This is
because the specified share may be write- protected.
Recommended
Response Action
To export the file, change the permissions on the remote share. Else, create another share with
write permissions.
888