Reference Guide

Arguments
arg1 =
sensor name
arg2 =
current
Detailed
Description
The current sensor identified in the message has returned to a normal state.
Recommended
Response Action
No response action is required.
Category System Health
SubCategory AMP = Amperage
Severity Severity 3 (Informational)
Trap/EventID FALSE
LCD Message No LCD message display defined.
Initial Default. TRUE
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
DONTKN
OW
FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE
AMP403
Message The
arg1
sensor state has changed to a warning state with a value of
arg2
A.
Arguments
arg1 =
sensor name
arg2 =
current
Detailed
Description
The current sensor identified in the message is faulty or the current drawn by the system
exceeds the warning threshold. This condition can cause system performance issues and
degradation in the moitoring capability of the system.
Recommended
Response Action
Verify the Embedded System Management (ESM) Log for any sensor related faults. If there is a
failed sensor, replace the system board. For more information, contact your service provider.
Otherwise, change the warning threshold for the current sensor such that it corresponds to the
hardware configuration.
Category System Health
SubCategory AMP = Amperage
Severity Severity 2 (Warning)
Trap/EventID FALSE
LCD Message No LCD message display defined.
Initial Default. TRUE
88