Reference Guide

Detailed
Description
The current sensor identified in the message has failed. This condition can cause system
performance issues and degradation in the moitoring capability of the system.
Recommended
Response Action
Check the Embedded System Management (ESM) Log for any sensor related faults. If there is a
failed sensor, replace the system board. For more information, contact your service provider.
Category System Health
SubCategory AMP = Amperage
Severity Severity 1 (Critical)
Trap/EventID FALSE
LCD Message No LCD message display defined.
Initial Default. TRUE
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
DONTKN
OW
FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE
AMP401
Message Unable to read the
arg1
sensor value.
Arguments
arg1 =
sensor name
Detailed
Description
The current sensor identified in the message has failed. This condition can cause system
performance issues and degradation in the moitoring capability of the system.
Recommended
Response Action
Check the Embedded System Management (ESM) Log for any sensor related faults. If there is a
failed sensor, replace the system board. For more information, contact your service provider.
Category System Health
SubCategory AMP = Amperage
Severity Severity 2 (Warning)
Trap/EventID FALSE
LCD Message No LCD message display defined.
Initial Default. TRUE
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
DONTKN
OW
FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE
AMP402
Message The
arg1
sensor returned to a normal state with a value of
arg2
A.
87