Reference Guide

Detailed
Description
The vFlash partition is in-use by another process. Therefore, the current operation cannot
proceed.
Recommended
Response Action
Try the operation after a few minutes. If the problem persists, reset iDRAC and repeat the
operation.
Category Audit
SubCategory RAC = RAC Event
Severity Severity 3 (Informational)
Trap/EventID FALSE
LCD Message No LCD message display defined.
Initial Default. FALSE
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE
RAC0250
Message One or more partitions are read-only.
Detailed
Description
The vFlash partitions are read-only. Therefore, the current operation cannot proceed.
Recommended
Response Action
Make sure the partitions are writable before attempting to change their contents.
Category Audit
SubCategory RAC = RAC Event
Severity Severity 3 (Informational)
Trap/EventID FALSE
LCD Message No LCD message display defined.
Initial Default. FALSE
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE
RAC0251
Message One or more partitions are currently attached.
Detailed
Description
The vFlash partitions are attached. Therefore, the current operation cannot proceed.
Recommended
Response Action
Detach the partitions and try again.
853