Reference Guide

Detailed
Description
This error occurs if Lifecycle log events have not occurred recently.
Recommended
Response Action
No response action is required.
Category Storage
SubCategory RAC = RAC Event
Severity Severity 3 (Informational)
Trap/EventID FALSE
LCD Message No LCD message display defined.
Initial Default. FALSE
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE
RAC0511
Message There are no physical disks to be displayed.
Detailed
Description
Physical disks cannot be displayed. This error may occur if the host system is powered off,
physical disks are removed, or incorrect filters are applied.
Recommended
Response Action
1. Check if the host system is powered off or shutdown. 2. Check if the physical disks are
inserted into the enclosure or attached to the backplane. 3. Check if correct filters are applied.
4. Check that the Storage Enclosure is on. 5. verify that the adapter cables are properly
connected and there are no bent pins.
Category Storage
SubCategory RAC = RAC Event
Severity Severity 2 (Warning)
Trap/EventID FALSE
LCD Message No LCD message display defined.
Initial Default. FALSE
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE
RAC0512
Message There are no virtual disks to be displayed.
Detailed
Description
Virtual disks cannot be displayed. This error may occur if the host system is powered off, no
virtual disks were created, or incorrect filters are applied.
800