Reference Guide
PWR2401
Message Power management firmware initialization error
Detailed
Description
The iDRAC controller detected that the power management firmware did not initialize properly.
The system may operate in a performance degraded state.
Recommended
Response Action
"1) Disconnect system input power, wait one minute, reconnect system input power. 2) Re-flash
system BIOS. 3) Upgrade system BIOS to the latest revision."
Category System Health
SubCategory PWR = Power Usage
Severity Severity 1 (Critical)
Trap/EventID FALSE
LCD Message No LCD message display defined.
Initial Default. FALSE
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE
PWR2402
Message Power management firmware not responsive.
Detailed
Description
The iDRAC controller cannot communicate with the power management firmware. The system
may operate in a performance degraded state.
Recommended
Response Action
"1) Disconnect system input power, wait one minute, reconnect system input power. 2) Re-flash
system BIOS. 3) Upgrade system BIOS to the latest revision."
Category System Health
SubCategory PWR = Power Usage
Severity Severity 1 (Critical)
Trap/EventID FALSE
LCD Message No LCD message display defined.
Initial Default. FALSE
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE
PWR2403
Message Power management firmware responsive
792