Reference Guide

Recommended
Response Action
No reponse action is required
Category System Health
SubCategory PSU = Power Supply
Severity Severity 3 (Informational)
Trap/EventID 2187
LCD Message No LCD message display defined.
Initial Default. FALSE
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
TRUE TRUE TRUE TRUE TRUE FALSE FALSE FALSE FALSE
PSU0039
Message An under current fault detected on power supply
arg1
.
Arguments
arg1 =
number
Detailed
Description
Insufficient amount of current to keep power supply operating at a normal levels.
Recommended
Response Action
1) Remove and re-install the power supply input cord. 2) Check power distribution or PSU input
source for anomalies. 3) If the issue persists, contact technical support. Refer to the product
documentation to choose a convenient contact method.
Category System Health
SubCategory PSU = Power Supply
Severity Severity 1 (Critical)
Trap/EventID 2185
LCD Message Under current fault detected on PSU <number>. Check PSU.
Initial Default. FALSE
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
TRUE TRUE TRUE TRUE TRUE FALSE TRUE TRUE TRUE
PSU0040
Message An output under voltage fault detected on power supply
arg1
.
Arguments
arg1 =
number
744