Reference Guide
SubCategory PSU = Power Supply
Severity Severity 1 (Critical)
Trap/EventID 2185
LCD Message An under voltage fault detected on PSU <number>. Check power source.
Initial Default. FALSE
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
TRUE TRUE TRUE TRUE TRUE FALSE TRUE TRUE TRUE
PSU0035
Message An over voltage fault detected on power supply
arg1
.
Arguments
•
arg1 =
number
Detailed
Description
None
Recommended
Response Action
Check input power, replace or re-install the power supply. If the issue persists, contact
technical support. Refer to the product documentation to choose a convenient contact method.
Category System Health
SubCategory PSU = Power Supply
Severity Severity 1 (Critical)
Trap/EventID 2185
LCD Message Over voltage fault on PSU <number>. Check PSU
Initial Default. FALSE
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
TRUE TRUE TRUE TRUE TRUE FALSE TRUE TRUE TRUE
PSU0036
Message An over current fault detected on power supply
arg1
.
Arguments
•
arg1 =
number
Detailed
Description
This failure may be the result of an electrical issue with cables or subsystem components in
the system.
Recommended
Response Action
1) Remove and re-install the power supply. 2) Check cables and subsystem components in the
system for damage. 3) If the issue persists, contact technical support. Refer to the product
documentation to choose a convenient contact method.
742