Reference Guide

Trap/EventID 2186
LCD Message No LCD message display defined.
Initial Default. FALSE
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
TRUE TRUE TRUE TRUE TRUE FALSE TRUE TRUE TRUE
PSU0033
Message The temperature for power supply
arg1
is outside of range.
Arguments
arg1 =
number
Detailed
Description
System performance may be degraded.
Recommended
Response Action
Check the system operating environment, including airflow and inlet temperature. Check
system logs for temperature and thermal component failures.
Category System Health
SubCategory PSU = Power Supply
Severity Severity 1 (Critical)
Trap/EventID 2185
LCD Message PSU <number> temperature outside of range. Check PSU
Initial Default. FALSE
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
TRUE TRUE TRUE TRUE TRUE FALSE TRUE TRUE TRUE
PSU0034
Message An under voltage fault detected on power supply
arg1
.
Arguments
arg1 =
number
Detailed
Description
This failure may be the result of an electrical issue with cables or subsystem components in
the system.
Recommended
Response Action
1) Remove and re-install the power supply. 2) Check cables and subsystem components in the
system for damage. 3) If the issue persists, contact technical support. Refer to the product
documentation to choose a convenient contact method.
Category System Health
741