Reference Guide

Detailed
Description
System performance and power redundancy may be degraded or lost.
Recommended
Response Action
Remove and re-install the power supply at the next service window. If the issue persists,
contact technical support. Refer to the product documentation to choose a convenient contact
method.
Category System Health
SubCategory PSU = Power Supply
Severity Severity 2 (Warning)
Trap/EventID 2186
LCD Message Predictive failure on PSU <number>. Check PSU
Initial Default. FALSE
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
TRUE TRUE TRUE TRUE TRUE FALSE TRUE TRUE TRUE
PSU0003
Message The power input for power supply
arg1
is lost.
Arguments
arg1 =
number
Detailed
Description
The power supply is installed correctly but an input source is not connected or is not
functional.
Recommended
Response Action
Verify the input source is attached to the power supply. Verify the input power is within the
operating requirements for the power supply.
Category System Health
SubCategory PSU = Power Supply
Severity Severity 1 (Critical)
Trap/EventID 2185
LCD Message Power input for PSU <number> is lost. Check PSU cables
Initial Default. FALSE
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
TRUE TRUE TRUE TRUE TRUE FALSE TRUE TRUE TRUE
PSU0004
Message The power input for power supply
arg1
is outside of range.
735