Reference Guide

36
PSU Event Messages
PSU1000
Message Power supply cable has been removed from
arg1
.
Arguments
arg1 =
PSU Sensor Name
Detailed
Description
The power supply unit is not receiving input AC power. The power cable may not be connected
properly or removed. This can happen if there is an AC failure or problems with the power strip
attached to the enclosure power supply.
Recommended
Response Action
Reconnect the power cable to the power supply unit if it was disconnected. Restore the input
AC power supply. Make sure the power supply is restored to the enclosure from the mains.
Category Storage
SubCategory PSU = Power Supply
Severity Severity 2 (Warning)
Trap/EventID 4234
LCD Message No LCD message display defined.
Initial Default. FALSE
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
TRUE FALSE TRUE TRUE TRUE FALSE FALSE FALSE FALSE
PSU1001
Message
arg1
has failed.
Arguments
arg1 =
PSU Sensor Name
Detailed
Description
The enclosure detected that a power supply unit has failed.
Recommended
Response Action
Check for other messages related to the state of the power supply unit/enclosure. These may
help determine the cause of this event. Contact technical support if the issue still persists.
Category Storage
SubCategory PSU = Power Supply
729