Reference Guide

Trap/EventID 2297
LCD Message Fault detected on drive <number>. Check drive.
Initial Default. FALSE
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
TRUE FALSE TRUE TRUE TRUE FALSE FALSE FALSE FALSE
PDR1102
Message A predictive failure detected on drive
arg1
.
Arguments
arg1 =
number
Detailed
Description
The controller received a SMART error from the drive. The drive is operational but needs
replacement.
Recommended
Response Action
The drive will need replacement at the next service window.
Category System Health
SubCategory PDR = Physical Disk
Severity Severity 2 (Warning)
Trap/EventID 2298
LCD Message No LCD message display defined.
Initial Default. FALSE
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
TRUE FALSE TRUE TRUE TRUE FALSE FALSE FALSE FALSE
PDR1103
Message Drive
arg1
is the hot-spare drive.
Arguments
arg1 =
number
Detailed
Description
None
Recommended
Response Action
No response action is required.
Category System Health
SubCategory PDR = Physical Disk
684