Reference Guide

Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
TRUE FALSE TRUE TRUE TRUE FALSE FALSE FALSE FALSE
PDR52
Message A redundant path is broken.
Detailed
Description
The controller has two connectors that are connected to the same enclosure. The
communication path on one connector has lost connection with the enclosure. The
communication path on the other connector is reporting this loss.
Recommended
Response Action
Make sure the cables are attached securely. See the Cables Attached Correctly section for
more information on checking the cables. Make sure both Enclosure Management Modules
(EMMs) are healthy.
Category Storage
SubCategory PDR = Physical Disk
Severity Severity 2 (Warning)
Trap/EventID 4346
LCD Message No LCD message display defined.
Initial Default. FALSE
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
TRUE FALSE TRUE FALSE TRUE FALSE FALSE FALSE FALSE
PDR53
Message A redundant path has been restored for
arg1
.
Arguments
arg1 =
PD Name
Detailed
Description
This alert is provided for informational purposes.
Recommended
Response Action
No response action is required.
Category Storage
SubCategory PDR = Physical Disk
Severity Severity 3 (Informational)
Trap/EventID 4347
LCD Message No LCD message display defined.
Initial Default. FALSE
649