Reference Guide

Severity Severity 1 (Critical)
Trap/EventID FALSE
LCD Message No LCD message display defined.
Initial Default. FALSE
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE
PDR3
Message
arg1
has failed.
Arguments
arg1 =
physical disk
Detailed
Description
A storage physical disk has failed.
Recommended
Response Action
Replace the failed disk.
Category Storage
SubCategory PDR = Physical Disk
Severity Severity 1 (Critical)
Trap/EventID 4345
LCD Message No LCD message display defined.
Initial Default. FALSE
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
TRUE FALSE TRUE TRUE TRUE FALSE FALSE FALSE FALSE
PDR30
Message A global hot spare failed.
arg1
Arguments
arg1 =
PD Name
Detailed
Description
The controller cannot to communicate with a disk that is assigned as a global hot spare. The
disk either failed or was removed. There may also be a bad or loose cable.
Recommended
Response Action
Verify that the disk is healthy and installed. Check the cables. Refer to the product
documentation and see the Cables Attached Correctly section for more information on
checking the cables. If necessary, replace the disk and reassign the global hot spare.
636