information. 4) If you cannot identify why the disk has reached an unacceptable temperature,
then replace the disk. If the physical disk is a member of a non-redundant virtual disk, then
back up the data before replacing the disk. Removing a physical disk that is included in a non-
redundant virtual disk causes the virtual disk to fail and may cause data loss.
Category Storage
SubCategory PDR = Physical Disk
Severity Severity 2 (Warning)
Trap/EventID FALSE
LCD Message No LCD message display defined.
Initial Default. FALSE
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE
PDR23
Message SMART warning degraded for
arg1
Arguments
arg1 =
PD Name
Detailed
Description
A disk is degraded and has received a SMART alert (predictive failure). The disk is likely to fail
in the near future.
Recommended
Response Action
Replace the disk that has received the SMART alert. If the physical disk is a member of a non-
redundant virtual disk, then back up the data before replacing the disk. Removing a physical
disk that is included in a non-redundant virtual disk will cause the virtual disk to fail and may
cause data loss.
Category Storage
SubCategory PDR = Physical Disk
Severity Severity 2 (Warning)
Trap/EventID FALSE
LCD Message No LCD message display defined.
Initial Default. FALSE
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE
PDR24
Message Failure prediction threshold exceeded on
arg1
due to test. No action needed.