Reference Guide

LCD Message No LCD message display defined.
Initial Default. FALSE
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE
PDR21
Message SMART warning for
arg1
Arguments
arg1 =
PD Name
Detailed
Description
A disk has received a SMART alert (predictive failure). The disk is likely to fail in the near
future.
Recommended
Response Action
Replace the disk that has received the SMART alert. If the physical disk is a member of a non-
redundant virtual disk, then back up the data before replacing the disk. Removing a physical
disk that is included in a non-redundant virtual disk will cause the virtual disk to fail and may
cause data loss.
Category Storage
SubCategory PDR = Physical Disk
Severity Severity 2 (Warning)
Trap/EventID FALSE
LCD Message No LCD message display defined.
Initial Default. FALSE
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE
PDR22
Message SMART warning temperature for
arg1
Arguments
arg1 =
PD Name
Detailed
Description
A disk has reached an unacceptable temperature and received a SMART alert (predictive
failure). The disk is likely to fail in the near future.
Recommended
Response Action
Do the following: 1) Determine why the physical disk reached an unacceptable temperature.
For example, a fan failure, incorrect thermostat settings, or the room temperature may be too
hot or cold. 2) Verify that the fans in the server or enclosure are working. 3) If the physical disk
is in an enclosure, check the thermostat settings and examine whether the enclosure is
located near a heat source. Verify the enclosure has enough ventilation and that the room
temperature is not too hot. Refer to the enclosure documentation for more diagnostic
631