Reference Guide

SubCategory PDR = Physical Disk
Severity Severity 2 (Warning)
Trap/EventID FALSE
LCD Message No LCD message display defined.
Initial Default. FALSE
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE
PDR11
Message
arg1
rebuild was cancelled.
Arguments
arg1 =
physical disk
Detailed
Description
A user has cancelled the rebuild operation.
Recommended
Response Action
Restart the rebuild operation.
Category Storage
SubCategory PDR = Physical Disk
Severity Severity 3 (Informational)
Trap/EventID FALSE
LCD Message No LCD message display defined.
Initial Default. FALSE
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE
PDR12
Message
arg1
initialization has failed.
Arguments
arg1 =
PD Name
Detailed
Description
The physical disk has failed or is corrupt.
Recommended
Response Action
Replace the failed or corrupt disk. Identify a disk that has failed by locating the disk that has a
red "X" for its status. Restart the initialization.
625