Reference Guide
Trap/EventID FALSE
LCD Message No LCD message display defined.
Initial Default. FALSE
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE
PDR100
Message Dedicated Hot Spare
arg1
no longer useful for all arrays.
Arguments
•
arg1 =
PD Name
Detailed
Description
The controller is not able to communicate with a disk that is assigned as a dedicated hot spare.
The disk may have been removed. There may also be a bad or loose cable.
Recommended
Response Action
Verify that the disk is healthy and that it has not been removed. Check the cables. See the
Cables Attached Correctly section for more information on checking the cables. If necessary,
replace the disk and reassign the dedicated hot spare.
Category Storage
SubCategory PDR = Physical Disk
Severity Severity 2 (Warning)
Trap/EventID FALSE
LCD Message No LCD message display defined.
Initial Default. FALSE
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE
PDR101
Message Global Hot Spare
arg1
does not cover all arrays.
Arguments
•
arg1 =
PD Name
Detailed
Description
This alert message occurs if there are arrays not protected with a global hot spare.
Recommended
Response Action
No response action is required.
Category Storage
624