Reference Guide
Recommended
Response Action
Reboot the system and enable System Services by pressing CTRL+E option when prompted to
do so in the POST. This launches the iDRAC configuration utility where Lifecycle Controller can
be enabled.
Category Configuration
SubCategory OSD = OS Deployment
Severity Severity 3 (Informational)
Trap/EventID FALSE
LCD Message No LCD message display defined.
Initial Default. FALSE
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE
OSD36
Message Boot to ISO Image has been cancelled by using CTRL+E option on the server.
Detailed
Description
User has cancelled system services by using the CTRL+E option (iDRAC configuration utility)
during POST. This action cancels the WSMAN request to boot to ISO.
Recommended
Response Action
To resolve the issue rerun the command. Do not cancel system services using CTRL+E during
POST when system is rebooting to the ISO.
Category Configuration
SubCategory OSD = OS Deployment
Severity Severity 2 (Warning)
Trap/EventID FALSE
LCD Message No LCD message display defined.
Initial Default. FALSE
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE
OSD37
Message ISO image size too large.
Detailed
Description
ISO Image size is bigger than the available size in VFlash.
Recommended
Response Action
1) Use a smaller size ISO Image. 2) Format the VFlash using the iDRAC GUI, RACADM, or iDRAC
configuration utility and then retry this command.
Category Configuration
575