Reference Guide
NIC009
Message Lifecycle Controller is currently in use.
Detailed
Description
Lifecycle Controller cannot gain access to internal storage due to use by another application or
operation.
Recommended
Response Action
Wait for current Lifecycle Controller operation to complete. Verify that the system is 1) Not
currently in Lifecycle Controller Unified Server Configurator 2) Not waiting for user intervention
at F1/F2 POST error 3) Not in any of the device or controller Option ROMs and retry the
operation.
Category Configuration
SubCategory NIC = NIC Config
Severity Severity 2 (Warning)
Trap/EventID FALSE
LCD Message No LCD message display defined.
Initial Default. FALSE
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE
NIC010
Message Lifecycle Controller is not enabled, cannot create Configuration job.
Detailed
Description
For 11G systems: System Services must be enabled to perform the requested operation.
System Services has been disabled through the iDRAC configuration utility accessed by
pressing CTRL+E on boot up or through a remote operation. For 12G systems: Lifecycle
Controller must be enabled to perform the requested operation. Lifecycle Controller has been
disabled by pressing F2 Setup, selecting iDRAC Configuration, and selecting Lifecycle
Controller Settings on boot up or through a remote operation.
Recommended
Response Action
For 11G systems: Use the iDRAC configuration utility to enable the System Services by pressing
on the CTRL+E option on boot up at the targeted system. For 12G systems: Use F2 Setup, select
iDRAC Configuration, and select Lifecycle Controller Settings, to enable the Lifecycle Controller
on boot up of the targeted system.
Category Configuration
SubCategory NIC = NIC Config
Severity Severity 2 (Warning)
Trap/EventID FALSE
LCD Message No LCD message display defined.
Initial Default. FALSE
546