Reference Guide
Detailed
Description
None
Recommended
Response Action
No response action is required.
Category System Health
SubCategory MEM = Memory
Severity Severity 3 (Informational)
Trap/EventID 2267
LCD Message No LCD message display defined.
Initial Default. FALSE
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
TRUE FALSE TRUE TRUE TRUE FALSE FALSE FALSE FALSE
MEM1208
Message Memory spare redundancy is lost. Check memory device at location
arg1
.
Arguments
•
arg1 =
location
Detailed
Description
The assigned spare is no longer available.
Recommended
Response Action
Review system logs for memory exceptions. Re-install memory at location <location>
Category System Health
SubCategory MEM = Memory
Severity Severity 1 (Critical)
Trap/EventID 2265
LCD Message Memory spared lost on <location>. Power cycle system
Initial Default. FALSE
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
TRUE FALSE TRUE TRUE TRUE FALSE FALSE FALSE FALSE
MEM1209
Message Memory spare redundancy is degraded. Check memory device at location
arg1
.
Arguments
•
arg1 =
location
531