Reference Guide

Trap/EventID FALSE
LCD Message No LCD message display defined.
Initial Default. FALSE
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE
LC018
Message Server certificate successfully modified. iDRAC will now restart and be unavailable during
restart.
Detailed
Description
The command was successful. Communication to iDRAC will be lost as iDRAC restarts to use
the new server certificate.
Recommended
Response Action
No response action is required.
Category Configuration
SubCategory LC = Lifecycle Contr
Severity Severity 3 (Informational)
Trap/EventID FALSE
LCD Message No LCD message display defined.
Initial Default. FALSE
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE
LC019
Message Base64 decode of PKCS12 content was not successful.
Detailed
Description
The PKCS12 string could not be decoded from the Base64 encoding into a PKCS12 binary file.
Recommended
Response Action
Validate that the contents of the PKCS12 parameter is base64 encoded. Openssl can be used to
validate the encoding.
Category Configuration
SubCategory LC = Lifecycle Contr
Severity Severity 2 (Warning)
Trap/EventID FALSE
LCD Message No LCD message display defined.
449