Reference Guide

Recommended
Response Action
No response action is required.
Category System Health
SubCategory HWC = Hardware Config
Severity Severity 3 (Informational)
Trap/EventID FALSE
LCD Message No LCD message display defined.
Initial Default. TRUE
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
DONTKN
OW
FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE
HWC8006
Message The SD card device state has changed to a warning state. SD card location:
arg1
, SD card
device type:
arg2
, SD card state:
arg3
.
Arguments
arg1 =
location
arg2 =
type
arg3 =
state
Detailed
Description
The SD card device is not functioning correctly, and its state has changed to a warning state.
Recommended
Response Action
Reinsert the SD card or try a different SD card and retry the operation. If the issue persists, do
one of the following to resolve the error: 1) If the SD card sensor is installed on the internal SD
module, replace the module. 2) If the SD card sensor is embedded on the system board,
replace the system board. . For more information, contact your service provider.
Category System Health
SubCategory HWC = Hardware Config
Severity Severity 2 (Warning)
Trap/EventID FALSE
LCD Message No LCD message display defined.
Initial Default. TRUE
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
DONTKN
OW
FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE
418